FILE NO. SVM-06009
Surface temp. of heat
exchanger interchanging
pipe
T
(°C)
5-4. RAS-24NKPX-T / RAS-24N2AX-T
Evaporator
Indoor unit
Cross flow fan
Cooling
Compressor
Condenser
Propeller fan
Outdoor unit
PH400X3CS-4KT1
Cooling
O.D.:15.88 mm O.D.:6.35 mm
Cooling
Gas container connection (Reinstall etc.)
Packed valve
(
6 .35)
Packed valve
(
1 5.88)
0.39 m
(Connecting pipe)
1 5.88
0.49 m
(Connecting pipe)
6.35
T
P
Refrigerant
R22 1.
68
kg
Mark ( ) means check points of Gas Leak
Capillary tube
2.4x700
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard 0.46 10.4 High 27/19 35/24
Cooling High temperature 0.56 13.8 High 32/23 43/26*
Low temperature
0.3
2 2.0 Low 21/15 21/15
Fan speed
(indoor)
50 Hz
Standard
pressure
P
(MPaG)
l
15