FILE NO. SVM-06009
Note : 1
Capacity is based on the following temperature conditions.
Note : 2
Charge refrigerant according to the table below.
Temperature
Condition
JIS B8615-1
Cooling Heating
Indoor unit inlet air temperature
(DB) 27°C 20°C
(WB) 19°C 15°C
Outdoor unit inlet air temperature
(DB) 35°C 7°C
(WB) 24°C 6°C
Refrigerant
RAS-24NKHP-E / RAS-24NAH-E
RAS-18NKPX-T / RAS-18N2AX-T
RAS-24NKPX-T / RAS-24N2AX-T
*1 No need to charge
15 m or less 15 m or less
extra refrigerant
*2 Need to charge
Over 15 m up to 25 m (30 g/m) Over 15 m up to 20 m (20 g/m)
extra refrigerant