14
FILE NO. SVM-09036
5-2. RAS-24SKP-ES / RAS-24SA-ES
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard 0.84 13.0 High 27/19 35/24
Cooling High temperature 1.01 17.0 High 32/23 43/26
Low temperature 0.65 5.0 Low 21/15 21/15
Fan speed
(indoor)
50 Hz
Standard
pressure
P
(MPaG)
Heat exchanger
Indoor unit
Cross flow fan
Cooling
Propeller fan
Outdoor unit
PA270X3CS-4MU2
Cooling
O.D.:12.7 mm O.D.:6.35 mm
Cooling
Gas container connection (Reinstall etc.)
Packed valve
(
6.35)
Packed valve
(
12.7 )
0.39 m
(Connecting pipe)
12.7
0.49 m
(Connecting pipe)
6 .35
T
P
Refrigerant
R410A 1.
70
kg
Compressor
Mark ( ) means check points of Gas Leak
Capillary tube
2.0x
1000 s
Surface temp. of heat
exchanger interchanging
pipe
T
(°C)
Heat exchanger