76
FILE NO. SVM-04008
10-4 Outdoor Unit (RAS-18UA-E3, RAS-18UAX3, RAS-18UA-AR3)
1) Stop the operation of the air conditioner and turn off
its main power supply or remove the power supply
cord.
2) Remove the electrical parts cover.
(2 screws 4 x 10L)
3) Remove 2 cord clamps (4 screws 4 x 22L) and
disconnect the power supply cord and connecting
cable after removing 6 screws on the terminal block
and 1 ground screw on the electrical parts base.
4) Remove the front cabinet. (8 scerws 4 x 10L)
(Pull the front lower portion toward you, and pull out
it upward to remove it.)
5) Remove the back cabinet. (4 screws 4 x 10L)
1) Perform the common procedure 1
2) Remove the capacitor band. (1 screw 4 x 10L)
3) Disconnect the lead wires from the capacitor
terminal.
1) Perform the common procedure 1
2) Remove the fixing screw. (1 screw 4 x 10L)
3) Disconnect the lead wires from the capacitor
terminal.
1) Perform the common procedure 1
2) Remove the fixing screw. (2 screws 4 x 10L)
3) Disconnect the lead wires from the terminal.
1) Perform the common procedure 1
2) Remove the fixing screw. (1 screw 4 x 10L)
3) Disconnect the lead wires from the terminal.
1 Common
procedure
2 Running
capacitor
for compressor
3 Running
capacitor
for fan motor
4
No. Part name Procedures Remarks
Remove
8 screws 4 x 10L
Spark killer
Running
capacitor for
compressor
Running
capacitor for
fan motor
Relay or
Magnetic
contactor
4 screws 4 x 22L 4 screws 4 x 10L
Magnetic contactor
Spark killer

Table of Contents