– 37 –
Item Operation flow and applicable data, etc. Description
2. Indoor fan
motor
control
3) In heating operation, the mode changes to [LL] if thermostat is
turned off.
4) If Ta 25°C when heating operation has started and when defrost
operation has been cleared, the air conditioner operates with (H)
mode or higher mode for 1 minute after Tc entered in E zone of cool
air discharge preventive control.
5) Self-clean operation
When performing self-clean operation after stopping the cooling
operation, the mode becomes 610 rpm (M07, 10, 13, 24 type), 630
rpm (M16, 22 type).
[Self-clean ] is displayed.
tap COOL HEAT
External static pressure selection
10Pa 20Pa 35Pa 45Pa
F1 HH 1080 1140 1240 1280
F2 HH 1080 1140 1240 1280
F3 H+ 1020 1080 1180 1220
F4 H+ 1020 1080 1180 1220
F5 H 950 1020 1100 1160
F6 H 950 1020 1100 1160
F7 L+ 890 960 1040 1100
F8 L+ 890 960 1040 1100
F9 L 830 890 970 1020
FA L 830 890 970 1020
FB L- 690 720 760 790
FC L- 690 720 760 790
FD LL LL 550 550 550 550
22 type
tap COOL HEAT
External static pressure selection
10Pa 20Pa 35Pa 45Pa
F1 HH 1120 1180 1280 1300
F2 HH 1120 1180 1280 1300
F3 H+ 1060 1120 1200 1260
F4 H+ 1060 1120 1200 1260
F5 H 980 1040 1120 1180
F6 H 980 1040 1120 1180
F7 L+ 920 980 1060 1100
F8 L+ 920 980 1060 1100
F9 L 840 900 980 1020
FA L 840 900 980 1020
FB 700 730 770 790
FC 700 730 770 790
FD LL LL 550 550 550 610
24 type