7. REFRIGERANT CYCLE DIAGRAM
7-1. Refrigerant Cycle Diagram
NOTE :
The maximum pipe length of this air conditioner is 40 m. The additional chaging of refrigerant is unnecessary
because this air cinditioner is designed with charge-less specification.
Connecting pipe
Thickness : 0.8 mm
Ø9.52 :
RAS-M10GKCVP-E
RAS-M13GKCVP-E
Ø12.7 :
RAS-M16GKCVP-E
NOTE :
Gas leak check position
Refrigerant flow
INDOOR UNIT A
T1
Temp. measurement
To
C room
To
B room
Indoor heat
exchanger
Cross flow fan
Sectional shape
of heat insulator
To
C room
To
B room
Allowable height
difference : 10m
Allowable pipe length
Per 1 unit
Max. : 20m
Min. : 2m
Total
Max. : 40m
P
Strainer
Pulse motor valve
at liquid side
(CAM-B22YGTF)
TGaTGbTGc
TD
Accumulating tank
Ø51 x 300
(460cc)
Compressor
DA130A1F-25F
T
2
Outdoor heat
exchanger
Temp. measurement
Propeller fan
Refrigerant amount : 1.5kg (R410A)
OUTDOOR UNIT
Connecting pipe
Thickness : 0.8 mm
Ø6.35
Pressure
measurement
Gauge attaching port
Vacuum pump
connecting port
(Ø9.52) (Ø9.52) (Ø12.7) (Ø6.35) (Ø6.35) (Ø6.35)