– 7 –
2-2. Specifications of Performance When Each Indoor Unit is Combined with Other Unit
Indoor unit Unit ca
(V)
ABCABC
Cooling
capacity
(kW)
Power
consum
tion
(W)
Operation
current
(A)
Outdoor
noise
(dB)
220 10 ——2.7 ——
2.7
(1.4 to 3.2)
770
(320 to 950)
4.12
45
230 10 ——2.7 ——
2.7
(1.4 to 3.2)
770
(320 to 950)
3.94
45
240 10 ——2.7 ——
2.7
(1.4 to 3.2)
770
(320 to 950)
3.77
45
220 13 ——3.7 ——
3.7
(1.4 to 4.4)
1200
48
230 13 ——3.7 ——
3.7
(1.4 to 4.4)
1200
48
240 13 ——3.7 ——
3.7
(1.4 to 4.4)
1200
48
220 16 ——4.5 ——
4.5
(1.4 to 4.9)
1600
48
230 16 ——4.5 ——
4.5
(1.4 to 4.9)
1600
48
1 unit
240 16 ——4.5 ——
4.5
(1.4 to 4.9)
1600
48
220 10 10 — 2.7 2.7 —
5.4
(1.8 to 6.0)
1500
48
230 10 10 — 2.7 2.7 —
5.4
(1.8 to 6.0)
1500
48
240 10 10 — 2.7 2.7 —
5.4
(1.8 to 6.0)
1500
48
220 10 13 — 2.45 3.35 —
5.8
(1.8 to 6.3)
1800
48
230 10 13 — 2.45 3.35 —
5.8
(1.8 to 6.3)
1800
48
240 10 13 — 2.45 3.35 —
5.8
(1.8 to 6.3)
1800
48
220 10 16 — 2.21 3.69 —
5.9
(1.8 to 6.4)
1830
48
230 10 16 — 2.21 3.69 —
5.9
(1.8 to 6.4)
1830
48
240 10 16 — 2.21 3.69 —
5.9
(1.8 to 6.4)
1830
48
220 13 13 — 2.95 2.95 —
5.9
(1.8 to 6.4)
1830
48
230 13 13 — 2.95 2.95 —
5.9
(1.8 to 6.4)
1830
48
240 13 13 — 2.95 2.95 —
5.9
(1.8 to 6.4)
1830
48
220 13 16 — 2.71 3.29 —
6.0
(1.8 to 6.4)
1850
48
230 13 16 — 2.71 3.29 —
6.0
(1.8 to 6.4)
1850
48
240 13 16 — 2.71 3.29 —
6.0
(1.8 to 6.4)
1850
48
220 16 16 — 3.05 3.05 —
6.1
(1.8 to 6.5)
1870
48
230 16 16 — 3.05 3.05 —
6.1
(1.8 to 6.5)
1870
48
2 inits
240 16 16 — 3.05 3.05 —
6.1
(1.8 to 6.5)
1870
48
220 10 10 10 2.13 2.13 2.13
6.4
(2.2 to 7.0)
1880
48
230 10 10 10 2.13 2.13 2.13
6.4
(2.2 to 7.0)
1880
48
240 10 10 10 2.13 2.13 2.13
6.4
(2.2 to 7.0)
1880
48
220 10 10 13 1.99 1.99 2.72
6.7
(2.2 to 7.0)
2150
48
230 10 10 13 1.99 1.99 2.72
6.7
(2.2 to 7.0)
2150
48
240 10 10 13 1.99 1.99 2.72
6.7
(2.2 to 7.0)
2150
48
220 10 13 13 1.80 2.45 2.45
6.7
(2.2 to 7.0)
2150
48
230 10 13 13 1.80 2.45 2.45
6.7
(2.2 to 7.0)
2150
48
240 10 13 13 1.80 2.45 2.45
6.7
(2.2 to 7.0)
2150
48
220 10 10 16 1.83 1.83 3.04
6.7
(2.2 to 7.0)
2150
48
230 10 10 16 1.83 1.83 3.04
6.7
(2.2 to 7.0)
2150
48
3 units
240 10 10 16 1.83 1.83 3.04
6.7
(2.2 to 7.0)
2150
48
• The above specification values are those under the conditions that the indoor DB/WB = 27/19°C and the outdoor