Separate sold parts
• Connecting pipe (Liquid side)
(6.4 mm (diam.), Nominal (diam.) 1/4" thick 0.8 mm)
• Connecting pipe (Gas side)
(9.5 mm (diam.), Nominal (diam.) 3/8" thick 0.8 mm)
RAS-M10SMUV-E, RAS-M10SMUCV-E, RAS-M13SMUV-E, RAS-M13SMUCV-E
(12.7 mm (diam.), Nominal (diam.) 1/2" thick 0.8 mm)
RAS-M16SMUV-E, RAS-M16SMUCV-E
• Power supply cord
2.5 mm
2
(H07RN-F or 60245IEC66)
• Connecting wire
1.0 mm
2
(H07RN-F or 60245IEC66)
• Thermal insulation for refrigerant pipe (10 mm or more, thermal insulating foam polyethylene)
• Thermal insulation for drain pipe (10 mm or more, foam polyethylene)
• Drain pipe (Outer 26 mm (diam.))
• Tapes
• Grounding wire (1.6 mm (diam.) or more)
2 ACCESSORY PARTS AND PARTS TO BE PROCURED
LOCALLY
Accessory parts
Part name Q'ty Shape Usage
Installation Manual 1 This manual (Be sure to hand over to customers)
Wireless remote controller 1 —
Remote controller holder 1 —
Mounting screws for remote
controller holder
3.1 mm (diam.) × 16 mm
1—
Batteries (Manganese) 2 —
Heat insulating pipe 2 For heat insulation of pipe connecting section
Installation pattern 1
—
For confirmation of ceiling opening and main unit position
Installation gauge 2
For positioning of ceiling position (united with installation
pattern)
Pattern fixing screw 4 M5 × 16L For attach the installation pattern
Heat insulator 1 For heat insulation of drain connecting section
Washer 8 For hanging-down unit
Hose band 1 For connecting drain pipe
Flexible hose 1 For adjusting core-out of drain pipe
Heat insulator A 1 For sealing of wire connecting port
Heat insulator B 1 For sealing of wire connecting port
Owner’s Manual 1 (Be sure to hand over to customers)
Part name Q'ty Shape Usage
Ceiling panel 1 Model: RB-B11MC(W)E