EasyManua.ls Logo

Toshiba Strata CIX670 - Station Loop Lengths

Toshiba Strata CIX670
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix — Specifications
Reserve Power
Strata CIX General Description 12/07 169
Station Loop Lengths
In a single site installation, the Base and optional Expansion cabinets must be placed within the
allowed maximum distance of each other as designated by
Table 38.
Table 38 Station Loop Lengths
1
1. When the system is powered by backup battery, range may be less as the backup battery is discharged.
Mode
Maximum line length (24 AWG)
1 Pair
2
2. One-pair wiring must be used with BWDKU and BDKS and CIX40 digital circuits (see Figure 2). The BWDKU
and BDKS and CIX40 digital circuits do not support two pair wiring.
2 Pair (Not
Available for CIX40
or BDKS)
1 Pair plus
external power
3
3. Two-pair wiring or optional telephone power supply is required to achieve maximum range in all cases.
DP5000, DKT3000/3200 or DKT2000-series
1000 ft. (303m)
1000 ft. (303m) 1000 ft. (303m)
DP with DOCA
DKT with BVSU or DVSU
DP with DOCA-1A
DKT with BHEU or HHEU
DKT with BPCI
DKT with BPCI + BHEU
4
4. DP5000-series does not require BHEU for headset and does not support BPCI.
DP with DOCA
DKT with BVSU + BHEU
4
or DVSU + HHEU
4
DP with DKM5020 or LM5110
DKT with DADM3020 or DADM2020 (1
ADM)
2, 5
5. BDKS and BWDKU do not provide the power wire pair; an external power supply is required to achieve
maximum range (see “Digital Telephone DSS and DDCB External Power Connection” in Chapter 8 – MDF
circuit card Wiring of the Strata CIX I&M Manual).
675 ft. (204m)
DKT with DADM3020 or DADM2020 (2
ADMs)
2, 5
500 ft. (151m)
DDM5060 or DDSS3060, DDSS3060 or
DDSS2060
1000 ft. (303m)
1000 ft. (303m) 1000 ft. (303m)
BATI, RATI
n/a n/a
DDCB3
1000 ft. (303m) 1000 ft. (303m)
Standard telephones, voice mail, AA, etc.
Approx. 3000 ft.
(909 m) with 150
ohm device.
6
6. See manufacturer’s product specifications for exact resistance of device.
n/a n/a
Approx. 9000 ft.
(2727 m) with 150
ohm device.
6
Approx. 21000 ft.
(6363 m) with 150
ohm device.
6
IPT2010-SD
IPT2020-SD
IPT2008-SD
IPT1020-SD
The IP telephone interface is 10Base-T/100Base-TX and requires
CAT5/5e/6 twisted pair cabling.
The maximum distance between the IP telephone jack and the
ethernet device it connects to is 100 meters (328 ft.). This includes
the 3 meter (9.84 ft.) straight-through CAT5 cable (black) supplied
with the IP telephone. Ethernet devices include
MIPU / LIPU / BIPU-M2A, BIPU-M1A servers, routers, etc.

Table of Contents

Related product manuals