Capacities
System Capacities
Strata CIX General Description 12/07 43
CIX100 Maximum Capacity Configuration
Examples
Table 15 CIX100 Base Cabinet with Digital Telephones and Loop Start Line With or Without Caller ID
Table 16 CIX100 Base and Expansion Cabinet with Analog Loop Start Lines
Table 17 CIX100 Base Only: Digital Telephones and T1 and/or PRI lines
4 Universal Slots
40 Stations (Max.)
24 CO lines (Max.)
44 Stations + Analog loop start lines combined (Max.)
Stations Analog loop start lines
40
4 (none can have Caller ID)
32
8 (all can have Caller ID)
32
16 (none can have Caller ID)
16
16 (8 can have Caller ID)
24
1
1. Using ADKU.
8 (none can have Caller ID)
8 Universal Slots
72 Stations (Max.)
56 CO lines (Max.)
92 Stations + Analog Loop Start Lines combined (Max.)
Stations Analog loop start lines
72
20 (none can have Caller ID)
72
16 (8 can have Caller ID)
64
32 (none can have Caller ID)
64
24 (8 can have Caller ID)
64
16 (all can have Caller ID)
48
40 (none can have Caller ID)
48
32 (8 can have Caller ID)
48
24 (16 can have Caller ID)
32
48 (none can have Caller ID)
32
40 (8 can have Caller ID)
32
32(16 can have Caller ID)
32
24 (24 can have Caller ID)
16
32 (24 can have Caller ID)
4 Universal Slots
40 Stations (Max.)
48 lines (Max.)
64 Stations + T1 and/or PRI lines combined (Max.)
Stations T1 and/or PRI lines
40 24/23
32 40/40
16 48/46