8
n
Single outdoor unit
Voltage
Range
Compressor Fan Motor Power Supply
Heat Pump
Model
MMY-
Nominal
Voltage
(V-Ph-Hz)
Min Max RLA LRA kW FLA MCA MOCP ICF
MAP0501HT7
380-3-60 342 418 4.2 + 4.2 0.60 0.8 16.5 20 —
MAP0601HT7
380-3-60 342 418 4.8 + 4.8 0.60 0.8 16.5 20 —
MAP0801HT7
380-3-60 342 418 5.4 + 5.4 0.60 1.0 20.0 30 —
MAP1001HT7
380-3-60 342 418 6.9 + 6.9 0.60 1.1 22.5 30 —
MAP1201HT7
380-3-60 342 418 10.0 + 10.0 0.60 1.1 24.5 30 —
n
Combination of outdoor unit
Compressor
Voltage
Range
Unit No.1 Unit No.2 Unit No.3 Unit No.4
Fan Motor Power Supply
Heat Pump
Model
MMY-
Nominal
Voltage
(V-Ph-Hz)
Min Max RLA LRA RLA LRA RLA LRA RLA LRA kW FLA MCA MOCP ICF
AP1401HT7
380-3-603424185.4 + 5.4—4.8 + 4.8—————0.6 × 21.0 + 0.8 36.540—
AP1601HT7
380-3-603424185.4 + 5.2—5.4 + 5.4—————0.6 × 21.0 + 1.0 40.050—
AP1801HT7
380-3-603424186.9 + 6.9—5.4 + 5.4—————0.6 × 21.0 + 1.1 42.550—
AP2001HT7
380-3-603424186.9 + 6.9—6.9 + 6.9—————0.6 × 21.1 + 1.1 45.060—
AP2201HT7
380-3-60 342 418 5.4 + 5.4 — 5.4 + 5.4 — 4.8 + 4.8 — — — 0.6 × 3 1.0 + 1.0 + 0.8 56.5 70 —
AP2211HT7
380-3-6034241810.0 + 10.0—6.9 + 6.9—————0.6 × 21.1 + 1.1 47.060—
AP2401HT7
380-3-60 342 418 5.4 + 5.4 — 5.4 + 5.4 — 5.4 + 5.4 — — — 0.6 × 3 1.0 + 1.0 + 1.0 60.0 70 —
AP2411HT7
380-3-6034241810.0 + 10.0—10.0 + 10.0—————0.6 × 21.1 + 1.1 49.060—
AP2601HT7
380-3-60 342 418 6.9 + 6.9 — 5.4 + 5.4 — 5.4 + 5.4 — — — 0.6 × 3 1.1 + 1.1 + 1.0 62.5 70 —
AP2801HT7
380-3-60 342 418 6.9 + 6.9 — 6.9 + 6.9 — 5.4 + 5.4 — — — 0.6 × 3 1.1 + 1.1 + 1.0 65.0 80 —
AP3001HT7
380-3-60 342 418 6.9 + 6.9 — 6.9 + 6.9 — 6.9 + 6.9 — — — 0.6 × 3 1.1 + 1.1 + 1.1 67.5 80 —
AP3201HT7
380-3-60 342 418 5.4 + 5.4 — 5.4 + 5.4 — 5.4 + 5.4 — 5.4 + 5.4 — 0.6 × 4 1.0 + 1.0 + 1.0 + 1.0 80.0 90 —
AP3211HT7
380-3-60 342 418 10.0 + 10.0 — 6.9 + 6.9 — 6.9 + 6.9 — — — 0.6 × 3 1.1 + 1.1 + 1.1 69.5 80 —
AP3401HT7
380-3-60 342 418 6.9 + 6.9 — 5.4 + 5.4 — 5.4 + 5.4 — 5.4 + 5.4 — 0.6 × 4 1.1 + 1.0 + 1.0 + 1.0 82.5 100 —
AP3411HT7
380-3-60 342 418 10.0 + 10.0 — 10.0 + 10.0 — 6.9 + 6.9 — — — 0.6 × 3 1.1 + 1.1 + 1.1 71.5 80 —
AP3601HT7
380-3-60 342 418 6.9 + 6.9 — 6.9 + 6.9 — 5.4 + 5.4 — 5.4 + 5.4 — 0.6 × 4 1.1 + 1.1 + 1.0 + 1.0 85.0 100 —
AP3611HT7
380-3-60 342 418 10.0 + 10.0 — 10.0 + 10.0 — 10.0 + 10.0 — — — 0.6 × 3 1.1 + 1.1 + 1.1 73.5 90 —
AP3801HT7
380-3-60 342 418 6.9 + 6.9 — 6.9 + 9.9 — 6.9 + 6.9 — 5.4 + 5.4 — 0.6 × 4 1.1 + 1.1 + 1.1 + 1.0 87.5 100 —
AP4001HT7
380-3-60 342 418 6.9 + 6.9 — 6.9 + 6.9 — 6.9 + 6.9 — 6.9 + 6.9 — 0.6 × 4 1.1 + 1.1 + 1.1 + 1.1 90.0 100 —
AP4201HT7
380-3-60 342 418 10.0 + 10.0 — 6.9 + 6.9 — 6.9 + 6.9 — 6.9 + 6.9 — 0.6 × 4 1.1 + 1.1 + 1.1 + 1.1 92.0 110 —
AP4401HT7
380-3-60 342 418 10.0 + 10.0 — 10.0 + 10.0 — 6.9 + 6.9 — 6.9 + 6.9 — 0.6 × 4 1.1 + 1.1 + 1.1 + 1.1 94.0 110 —
AP4601HT7
380-3-60 342 418 10.0 + 10.0 — 10.0 + 10.0 — 10.0 + 10.0 — 6.9 + 6.9 — 0.6 × 4 1.1 + 1.1 + 1.1 + 1.1 96.0 110 —
AP4801HT7
380-3-60 342 418 10.0 + 10.0 — 10.0 + 10.0 — 10.0 + 10.0 — 10.0 + 10.0 — 0.6 × 4 1.1 + 1.1 + 1.1 + 1.1 98.0 110 —
NOTE :Legend MCA
MOCP
ICF
RLA
: Minimum Circuit Amps
: Maximum Overcurrent Protection (Amps)
: Maximum Instantaneous Current Flow Start
: Rated Load Amps
LRA
FLA
kW
: Locked Rotor Amps
: Full Load Amps
: Fan Motor Rated Output (kW)
RLA is based on the following conditions.
Indoor temperature : 27°C DB/19°C WB
Outdoor temperature : 35°C DB
60Hz