T3400, T3400CT
3-41
3.18 Log Utilities
3.18.1 Function Description
This function logs error information generated while a test is in progress and stores the results
in RAM. Data can be stored on a floppy disk or output to a printer. If power is turned off,
the error information will be lost. Error information is displayed in the following order:
1. Error count (CNT)
2. Test name (TS-NAME)
3. Subtest number (TS-NAME)
4. Pass count (PASS)
5. Error status (STS)
6. FDD/HDD or memory address (ADDR)
7. Write data (WD)
8. Read data (RD)
9. HDC status (HSTS)
10. Error status name ( ERROR STATUS NAME)
3.18.2 Operations
1. Select 5 in the DIAGNOSTIC MENU and press Enter to log error information
into RAM or a floppy disk. Error information is displayed in the following format:
XXXXX ERRORS
CNT TS-NAME PASS STS ADDR WD RD HSTS [STATUS NAME]
001 FDD 02 0000 103 00001 00 00 FDD - WRITE PROTECTED
001 FDD 01 0000 180 00001 00 00 FDD - TIME OUT ERROR
Address
Error status
Pass count HDC status
Subtest number Read data
Test name Write data
Error count Error status
name
[[1:Next,2:Prev,3:Exit,4:Clear,5:Print,6:FD Log Read,7:FD Log Write]]