E6581611
F-7
6
Table of parameters that can be changed using the guidance function
Prese
t
-
speed setting
auf=2
Motor 1&2 switching operation
auf=4
Motor constant setting guidance
auf=5























































6.1.4 Automatically adjusting acceleration/deceleration time
au1 : Automatic acceleration/deceleration
Function
This automatically adjusts acceleration and deceleration time in line with load.
Refer to section 5.2 for setting acceleration/ deceleration time manually.
 =
* Adjusts the acceleration/deceleration time automatically within the range of 1/8 to 8 times as long as the
time set with the  or , depending on the current rating of the inverter.
 =
* Automatically adjusts speed during acceleration only. During deceleration, speed is not adjusted
automatically but reduced at the rate set with .