E6581611
G-10
7
List of output terminal function settings
List of detection levels for output terminal selection
Parameter
programmed value
Function
Parameter
programmed value
Function
Positive
logic
Negative
logic
Positive
logic
Negative
logic
Frequency lower limit   Heavy load output
Frequency upper limit   Lower limit frequency stop
Low-speed detection signal   Power failure synchronized operation
Output frequency attainment signal
(acceleration/deceleration completed)
  Traverse in progress
Set frequency attainment signal   Traverse deceleration in progress
  Fault signal (trip output)   Parts replacement alarm
  Over-current detection pre-alarm   Over-torque detection pre-alarm
  Overload detection pre-alarm   Frequency setting mode selection 1/2
  Overheat detection pre-alarm   Panel / remote selection
  Overvoltage detection pre-alarm   Forced continuous operation in progress
  Power circuit undervoltage detection   Specified frequency operation in progress
  Small current detection   Signal in accordance of frequency
command
  Over-torque detection   Fault signal (output also at a retry waiting)
  Braking resistor overload pre-alarm   PTC input alarm signal
  Run/Stop   Factory specific coefficient *1
  Serious failure   Analog input break detection alarm
  Light failure   F terminal status
  Cooling fan ON/OFF   R terminal status
  In jogging operation   Cooling fan replacement alarm
  Operation panel / terminal block
operation
  Number of starting alarm
  Cumulative operation time alarm   Acceleration operation in progress
  Communication option
communication error
  Deceleration operation in progress
  Forward/reverse run   Constant speed operation in progress
  Ready for operation 1   DC braking in progress
  Ready for operation 2 to  Factory specific coefficient *1
  Brake release 180 181 Integral input power pulse output signal
  Pre-alarm 182 183 Shock monitoring pre-alarm signal
  RS485 communication error to  Factory specific coefficient *1
  Designated data output 1  Always OFF
  Designated data output 2  Always ON
  Light load output
*1: Factory specific coefficients are manufacturer setting menus. Do not change the value of these parameters.
<Explanation of terminology>
Alarm …... Alarm output when a setting has been exceeded.
Pre-alarm …... Alarm output when the inverter may cause a trip during continued operation.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VFS15-4037PL-W and is the answer not in the manual?

Toshiba TOSVERT VFS15-4037PL-W Specifications

General IconGeneral
BrandToshiba
ModelTOSVERT VFS15-4037PL-W
CategoryInverter
LanguageEnglish

Related product manuals