TR-Electronic LMRS-34-350 IO-Link Ex - User Manual

Default Icon
87 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
TR-Electronic GmbH
Eglishalde 6
78647 Trossingen
Tel. +49 (0) 7425 228-0
info@tr-electronic.de
www.tr-electronic.de
Änderungen vorbehalten.
Seite 1/1
Gesamtbedienungsanleitung
Für
LMRS_34*350 IO-Link Ex
Material Nr.
346-00001
Generiert am
02.09.2023
Enthält Originalbedienungsanleitung
Dokumentationsabschnitte
EX-Benutzerhandbuch
de
LMRS-34, EX-Benutzerhandbuch 3G/3D
TR-ELA-BA-D-0031-03.pdf
Betriebsanleitung
de/en
LMP-30, LM_S-34 IO-Link
TR-ELA-BA-DGB-0026-04.pdf
Konformitätserklärung
de/en
LMRS-34, LP-46K, ATEX
TR-ELA-KE-DGB-0071-02.pdf
Technische Daten

Table of Contents

Questions and Answers

  • C
    Carla BairdAug 17, 2025
    What to do if TR-Electronic Media Converter shows position skips of the measuring system?
    • J
      jeremypetersonAug 17, 2025
      If the TR-Electronic Media Converter shows position skips of the measuring system, it could be due to strong vibrations or electrical faults (EMC). For strong vibrations, dampen impacts and shocks using shock modules. If the issue persists, replace the measuring system. For electrical faults, use isolated flanges and couplings made of plastic, as well as shielded cables with twisted pair wires for data and supply.
  • B
    Brian PattonAug 20, 2025
    What to do if TR-Electronic LMRS-34-350 IO-Link Ex displays 'Device application error, no details'?
    • C
      Craig MurrayAug 20, 2025
      If the TR-Electronic Media Converter displays a 'Device application error, no details' message, repeat service by turning the device OFF and then ON. If the error persists, the device must be replaced.
  • A
    Amanda PatrickAug 23, 2025
    What to do if TR-Electronic Media Converter service is temporarily not available?
    • S
      stephanie83Aug 23, 2025
      If the TR-Electronic Media Converter service is temporarily unavailable, check the device's operational status and repeat the service by turning the device OFF and then ON.
  • L
    Leslie SchroederAug 26, 2025
    What to do if TR-Electronic Media Converter function is temporarily unavailable?
    • M
      Michael ColeAug 26, 2025
      If the TR-Electronic Media Converter function is temporarily unavailable, check the device's operational status and repeat the service by turning the device OFF and then ON.
  • T
    Tamara MartinezAug 28, 2025
    What to do if TR-Electronic LMRS-34-350 IO-Link Ex Media Converter shows 'Service temporarily not available, local control'?
    • S
      Sandra FordAug 28, 2025
      If the TR-Electronic Media Converter shows 'Service temporarily not available, local control', block external access via the device control panel and repeat the service by turning the device OFF and then ON.
  • A
    Ashley MorganAug 31, 2025
    What to do if TR-Electronic LMRS-34-350 IO-Link Ex Media Converter shows 'Service temporarily not available, device control'?
    • K
      Kimberly HullAug 31, 2025
      If the TR-Electronic Media Converter shows 'Service temporarily not available, device control', block remote access and repeat the service by turning the device OFF and then ON.
  • R
    Robert McdanielSep 2, 2025
    What to do if TR-Electronic LMRS-34-350 IO-Link Ex Media Converter displays 'Application not ready'?
    • B
      Brett OlsonSep 2, 2025
      If the TR-Electronic Media Converter displays 'Application not ready', wait for the complete initialization (start-up phase) and repeat the service by turning the device OFF and then ON.
  • J
    John HuertaSep 5, 2025
    What to do if TR-Electronic LMRS-34-350 IO-Link Ex displays 'Process variable range over-run'?
    • J
      Jennifer MillerSep 5, 2025
      If the TR-Electronic Media Converter displays 'Process variable range over-run', move the magnet into the permissible measuring range.
  • C
    Christopher CooperSep 8, 2025
    What to do if TR-Electronic LMRS-34-350 IO-Link Ex Media Converter displays 'Measurement range over-run'?
    • A
      ahartmanSep 8, 2025
      If the TR-Electronic Media Converter displays 'Measurement range over-run', move the magnet into the permissible measuring range.
  • P
    Philip SpencerSep 12, 2025
    What to do if TR-Electronic LMRS-34-350 IO-Link Ex Media Converter displays 'Process variable range under-run'?
    • D
      dbutlerSep 12, 2025
      If the TR-Electronic Media Converter displays 'Process variable range under-run', move the magnet into the permissible measuring range.

TR-Electronic LMRS-34-350 IO-Link Ex Specifications

General IconGeneral
ModelLMRS-34-350 IO-Link Ex
Measuring Length350 mm
InterfaceIO-Link
Protection ClassIP67
Product TypeLinear Encoder
Operating Voltage18 ... 30 VDC
Housing MaterialAluminum
Operating Temperature-20°C ... +70°C