EasyManua.ls Logo

TR-Electronic LMRB-48 - User Manual

Default Icon
93 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
TR-Electronic GmbH
Eglishalde 6
78647 Trossingen
Tel. +49 (0) 7425 228-0
info@tr-electronic.de
www.tr-electronic.de
Änderungen vorbehalten.
Seite 1/1
Gesamtbedienungsanleitung
Für
LMRI_46*480 ANA_I+JUSTAGE
Material Nr.
339-00057
Generiert am
19.08.2023
Enthält Originalbedienungsanleitung
Dokumentationsabschnitte
Montageanleitung
de/en
Montage, Magnetostriktion - linear Encod
TR-ELA-BA-DGB-0004-16.pdf
Betriebsanleitung
de/en
Baureihe 46/34/27/48/70/80 Analog
TR-ELA-BA-DGB-0025-10.pdf
Konformitätserklärung
de/en
EU-Konformitätserklärung ELA (EMV+RoHS)
TR-ELA-KE-DGB-0079-02.pdf
Konformitätserklärung
de/en
UKCA, Konformitätserkl. ELA (EMV+RoHS)
TR-ELA-KE-GB-0080-02.pdf
Technische Daten

Table of Contents

Questions and Answers

  • L
    Leslie LloydAug 17, 2025
    What to do if TR-Electronic LMRB-48 Media Converter shows position skips of the measuring system?
    • D
      Daniel SmithAug 17, 2025
      If the TR-Electronic Media Converter shows position skips of the measuring system, it could be due to strong vibrations or electrical faults (EMC). For strong vibrations, dampen impacts and shocks using shock modules. If the issue persists, replace the measuring system. For electrical faults, use isolated flanges and couplings made of plastic, as well as shielded cables with twisted pair wires for data and supply.
  • J
    johnsondianeAug 20, 2025
    What to do if TR-Electronic Media Converter displays 'Device application error, no details'?
    • M
      mooredavidAug 20, 2025
      If the TR-Electronic Media Converter displays a 'Device application error, no details' message, repeat service by turning the device OFF and then ON. If the error persists, the device must be replaced.
  • D
    Donald BrownAug 23, 2025
    What to do if TR-Electronic LMRB-48 service is temporarily not available?
    • B
      bethmasonAug 23, 2025
      If the TR-Electronic Media Converter service is temporarily unavailable, check the device's operational status and repeat the service by turning the device OFF and then ON.
  • D
    Diana MartinezAug 26, 2025
    What to do if TR-Electronic LMRB-48 function is temporarily unavailable?
    • B
      Beth MartinAug 26, 2025
      If the TR-Electronic Media Converter function is temporarily unavailable, check the device's operational status and repeat the service by turning the device OFF and then ON.
  • P
    Paul WheelerAug 28, 2025
    What to do if TR-Electronic LMRB-48 Media Converter shows 'Service temporarily not available, local control'?
    • K
      Kristen SmithAug 28, 2025
      If the TR-Electronic Media Converter shows 'Service temporarily not available, local control', block external access via the device control panel and repeat the service by turning the device OFF and then ON.
  • D
    dsilvaAug 31, 2025
    What to do if TR-Electronic Media Converter shows 'Service temporarily not available, device control'?
    • T
      Tyler MoranAug 31, 2025
      If the TR-Electronic Media Converter shows 'Service temporarily not available, device control', block remote access and repeat the service by turning the device OFF and then ON.
  • V
    Virginia WelchSep 2, 2025
    What to do if TR-Electronic LMRB-48 Media Converter displays 'Application not ready'?
    • J
      Jerry CoffeySep 3, 2025
      If the TR-Electronic Media Converter displays 'Application not ready', wait for the complete initialization (start-up phase) and repeat the service by turning the device OFF and then ON.
  • K
    kelly38Sep 5, 2025
    What to do if TR-Electronic LMRB-48 displays 'Process variable range over-run'?
    • D
      Dakota BaxterSep 5, 2025
      If the TR-Electronic Media Converter displays 'Process variable range over-run', move the magnet into the permissible measuring range.
  • C
    chavezmelissaSep 8, 2025
    What to do if TR-Electronic LMRB-48 Media Converter displays 'Measurement range over-run'?
    • V
      valenciastephanieSep 8, 2025
      If the TR-Electronic Media Converter displays 'Measurement range over-run', move the magnet into the permissible measuring range.
  • A
    agonzalezSep 12, 2025
    What to do if TR-Electronic LMRB-48 Media Converter displays 'Process variable range under-run'?
    • J
      Joshua WareSep 12, 2025
      If the TR-Electronic Media Converter displays 'Process variable range under-run', move the magnet into the permissible measuring range.

TR-Electronic LMRB-48 Specifications

General IconGeneral
CategoryMedia Converter
ModelLMRB-48
ManufacturerTR-Electronic
Power Supply24 VDC
Protection ClassIP20

Related product manuals