TR-Electronic GmbH 2015, All Rights Reserved Printed in the Federal Republic of Germany
Page 24 of 28 TR-ELA-BA-DGB-0025 v10 08/02/2022
4 Analog interface
4.1 Measuring system version with Analog-Voltage
Over the analog interface the measuring system position can be output as voltage
value.
Analog Voltage, Position / Speed
Legend
U
O
= actual measured output voltage [V] *
SP = Start point
EP = End point
Pos = Measuring system position
R
L
= Load resistor []
R
line
= Line resistance []
R
total
= Total resistance [] = R
line
+ R
L
, > 1 k
* signed