Basic safety instructions
TR-Electronic GmbH 2017, All Rights Reserved Printed in the Federal Republic of Germany
Page 10 of 26 TR - ELA - BA - GB - 0021 - 04 06/26/2018
2.2 Obligation of the operator prior to commissioning
As an electronic device and for use in potentially explosive areas, the explosion
protection enclosure with integrated measuring system is subject to the provisions of
the EU-directives EMC and ATEX.
Therefore commissioning of the device is only allowed once it has been established
that the system/machine in which the device is to be installed, complies with the
provisions of the EU-directives EMC and ATEX, the harmonized standards, European
standards or the respective national standards.
2.3 General dangers with the use of this product
The product, hereafter referred to as equipment is manufactured using the latest
technology and according to recognized safety regulations. Nevertheless, non-
intended use can cause danger to life and limb of the user or third parties or
cause damage to the equipment and other property!
Only use the equipment for its intended use, with safety- and danger awareness and
in compliance with the
-user manual and the interface specific user manual!
The operator of an electrical system in a potentially explosive environment should
keep the equipment in a proper condition, it should be properly operated and
monitored and maintenance- as well as repairs are to be performed. This also
includes inspection of the equipment for possible transport damage prior to
commissioning.
Power connections may not be connected or disconnected with the power engaged.
Generally, wiring work as well as opening and closing of electrical connections may
only be performed with the power switched off.
The equipment may not be used in case of defects, as a basic principle it may not be
opened and dust deposits > 2 mm must be removed.