5 Assembly
Dimensions must be taken from the customer-specific drawing
Before mounting TR-linear-Transducer, make sure there are no strong magnetic and
electric interference fields in the vicinity.
Inadmissible interference fields can influence the measuring precision. The field
strength may be max. 3 mT in the vicinity of the measuring rod.
5.1 Mechanics profile- housing design
Since the position sensor by the measuring body mechanically one leads, is relatively
simple the installation the TR-linear-Transducer system. The exact guidance of the
captive-sliding magnet and non-contact and wear free measurement system each
other optimally. In order to reduce the wear between captive-sliding magnet and
measuring body to a minimum, the dimensional tolerances for angle and parallel
misalignment must be absolutely kept.
The exact of the measured value depends also on the symmetry of magnetic field
geometry. If no captive-sliding magnet is used, the position sensor must be led exactly
in axial direction to the measuring body. The admissible maximum distance between