EasyManua.ls Logo

Trane 22 Series - Electrical Connections at the Outdoor Unit

Trane 22 Series
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INDOOR UNIT D
INDOOR UNIT C
INDOOR UNIT B
INDOOR UNIT A
X
T
3
N
(
1
)
N
(
1
)
X
T
4
N
(
1
)
X
T
2
X
T
1
2
3
P
E
X
T
N
(
1
)
OUTDOOR UNIT
P
O
W
E
R
L
1
L
2
L
2
L
1
2
3
2
3
2
3
N
(
1
)
2
3
N
(
1
)
2
3
N
(
1
)
2
3
N
(
1
)
2
3
P
E
P
E
P
E
P
E
INDOOR UNIT D
INDOOR UNIT C
INDOOR UNIT B
INDOOR UNIT A
X
T
3
N
(
1
)
N
(
1
)
X
T
4
N
(
1
)
X
T
2
X
T
1
2
3
P
E
X
T
N
(
1
)
OUTDOOR UNIT
P
O
W
E
R
L
1
L
2
L2
L
1
2
3
2
3
2
3
N
(
1
)
2
3
N
(
1
)
2
3
N
(
1
)
2
3
N
(
1
)
2
3
P
E
P
E
P
E
P
E
X
T
5
N
(
1
)
2
3
INDOOR UNIT E
N
(
1
)
2
3
P
E
24K Model
30-42K Model
Electrical Connections at Outdoor Unit
L1
L2
L1 L2
L1
L2
L1 L2
C
C
18K Model
21K Model
For all models, terminals N(1) and 3 are for power; terminal 2 is for communication.
It is recommended to use a different wire color for each terminal connection in order to reduce
the risk of miswiring.
28
22 Series Multi-Zone

Related product manuals