Service Facts
© Trane 2008
PRODUCT SPECIFICATIONS
MODEL
RATED VOLTS/PH/HZ.
RATINGS 1
INDOOR COIL — Type
Rows — F.P.I.
Face Area (sq. ft.)
Tube Size (in.)
Refrigerant Control
Drain Conn. Size (in.) 2
DUCT CONNECTIONS
INDOOR FAN — Type
Diameter-Width (In.)
No. Used
Drive - No. Speeds
CFM vs. in. w.g.
No. Motors — H.P.
Motor Speed R.P.M.
Volts/Ph/Hz
F.L. Amps
FILTER
Vertical Applications
Filter Furnished?
Type Recommended
No.-Size-Thickness
Horizontal Applications
Filter Furnished?
Recommended Size
REFRIGERANT
Ref. Line Connections
Coupling or Conn. Size — in. Gas
Coupling or Conn. Size — in. Liq.
DIMENSIONS
Crated (In.)
Uncrated
WEIGHT
Shipping (Lbs.) / Net (Lbs.)
TEE3C49A-SF-1B
Convertible Variable Speed –
Communicating Air Handlers
2/4TEE3C49A1000A
TEE3C49A-SF-1B
2/4TEE3C49A1000A
200-230/1/60
See O.D. Specifications
Plate Fin
4 — 14.0
6.19
3/8 - Copper
TXV - Non-Bleed 4
3/4 NPT
See Outline Drawing 5
Centrifugal
10 x 10
1
Direct - Serial ECM
See Fan Performance Table
1 — 3/4
Variable
200-230/1/60
6.8
Yes
Low Velocity
1 - 20 X 25 - 1 in.
See Note 6
See Note 3
R-22 R-410A
Brazed Brazed
1-1/8 7/8
3/8 3/8
H x W x D
59-1/2 x 28-1/2 x 23-1/2
57-7/8 x 26 x 21
188 / 173
AIRFLOW ADJUSTMENT
If the airflow needs to be increased or decreased, see
the Airflow Label on the air handler or the Blower Per-
formance table in these Service Facts. Information on
changing the speed of the blower motor for your specific
outdoor model size is in the Blower Performance Table
or User Interface Menu.
Blower speed changes are made with the User Interface
Menu mounted in the control box.
CAUTION
!
RECONNECT ALL GROUNDING DEVICES.
All parts of this product that are capable of conducting
electrical current are grounded. If grounding wires,
screws, straps, clips, nuts, or washers used to com-
plete a path to ground are removed for service, they
must be returned to their original position and prop-
erly fastened.
HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING
WARNING:
IMPORTANT — This document contains a wiring diagram
and service information. This is customer property and is
to remain with this unit. Please return to service information
pack upon completion of work.
WARNING
!
THIS INFORMATION IS INTENDED FOR USE BY INDI-
VIDUALS POSSESSING ADEQUATE BACKGROUNDS
OF ELECTRICAL AND MECHANICAL EXPERIENCE.
ANY ATTEMPT TO REPAIR A CENTRAL AIR CONDI-
TIONING PRODUCT MAY RESULT IN PERSONAL IN-
JURY AND OR PROPERTY DAMAGE. The manufacturer
or seller cannot be responsible for the interpretation of
this information, nor can it assume any liability in con-
nection with its use.
1 These Air Handlers are A.R.I. certified with various Split System Air Condi-
tioners and Heat Pumps (ARI STANDARD 210/240). Refer to the Split Sys-
tem Outdoor Unit Product Data Guides for performance data.
2 3/4" Male Plastic Pipe (Ref.: ASTM 1785-76)
3 Minimum filter size for horizontal applications will be based on airflow selec-
tion and will be calculated as follows:
Low Velocity Filter: Face area (Sq. Ft.) = CFM / 300
High Velocity Filter: Face area (Sq. Ft.) = CFM / 500
4 Torque Spec for TXV = Tighten 1/6 turn past finger tight
5 See Installer's Guide for drawings
6 For customer ease of filter maintenance, it is recommended that a properly
sized, remote filter and grille be installed for horizontal applications. Airflow
should not exceed the face value of the filter being used. The factory in-
stalled filter should then be removed from the unit.
Question and Answer IconNeed help?

Do you have a question about the Trane 4TEE3C49A1000A and is the answer not in the manual?

Trane 4TEE3C49A1000A Specifications

General IconGeneral
Model4TEE3C49A1000A
RefrigerantR-410A
Voltage208/230V
Phase1
CabinetGalvanized steel
TypeAir Handler
Maximum External Static Pressure0.8 in. w.c.
InsulationFoil-faced fiberglass
Width21 in.

Summary

Product Specifications

Detailed Product Specifications

Technical details including model, ratings, coil, fan, filter, refrigerant, and dimensions for the air handler.

Airflow Adjustment

Blower Speed Adjustment

Information on adjusting blower speed via the User Interface Menu for optimal airflow settings.

Airflow and Performance Data

Airflow Performance Tables

Charts detailing airflow vs. static pressure for various outdoor unit sizes and speeds.

Heater Pressure Drop Data

Data on pressure drop for electric heater accessories across different models and airflow ranges.

Unit Test Mode

Air Handler Unit Test Procedure

Steps to initiate and run the air handler's diagnostic test mode via the User Interface.

User Interface Menu Navigation

Setup Menu Options

Guide to configuring settings like Cooling CFM, CFM per Ton, Heat CFM, and factory defaults.

Information Menu Options

Accessing system status, faults, alerts, sensor data, motor RPM, and part lists.

User Interface 24V Mode Configuration

24V Mode Setup Options

Configuring cooling/heating CFM, stages, fan delays, and factory defaults for 24V mode.

Air Handler Flash Codes

Alert Code Descriptions

Detailed explanations of alert codes, their corresponding LEDs, UI display, and alert groups.

Wiring Diagram and Legend

Wiring Diagram Details

Schematic illustrating electrical connections for the air handler model.

Wiring Legend and Notes

Explanation of symbols, wire colors, terminal functions, and important wiring notes.

Outline Drawings and Clearances

Unit Outline Drawings

Dimensional drawings showing top, side, bottom, and vertical views of the air handler.

Minimum Unit Clearance Table

Required and recommended clearances for combustible materials and service access.