|nsta||er's Guide
CHECKOUT PROCEDURE
After installation has been completed, it is recommended that the entire system be checked against the following list:
1. Refrigerant Line, Leak checked .................................. [
2. Suction Lines and Fittings properly insulated ........... [
3. Have all Refi'igerant Lines been secured and
isolated properly? ........................................................ [
4. Have passages through masonry been sealed?
If mortar is used, prevent mortar from coming
into direct contact with copper tubing ........................ [
5. Verify tightness of all electrical connects ................... [
6. Observe outdoor fhn during on cycle for clearance
and smooth operation .................................................. [
7. Indoor coil drain line drains freely. Pour water
into drain pan .............................................................. [
] 8. Supply registers and return _'illes open and
] unobstructed ................................................................ [ ]
9. Return air filter installed ............................................ [ ]
] 10. Thermostat thermometer is accurate. Check
against a reliable thermometer. Adjust per
instructions with thermostat ...................................... [ ]
] 11. Is correct speed tap being used?
] (Indoor blower motor) .................................................. [ ]
12. Operate complete system in each mode to
insure safe operation ................................................... [ ]
CHECKOUT PROCEDURE WiTH MAiN P(
Step
No.
TO CHECK
1 SumpHeat
2 IndoorFanOperation
3 CoolingOperation
4 CheckingPerformance
& Charge
5 Heating@
6
Off
iNDOORTHERMOSTAT
SWITCHSETTING
@ @ FanSwitch
Cool Heat Auto On
X X
)WER DISCONNECTS CLOSED (ON)
COMPONENTOPERATION
indoor Outdoor
Blower Fan
Runs Runs
Compressor @ Comp. Furnace
Runs Sump Heat
Heater Comes On
X
X
X
X
X
X
X X X X
x Ix I x I x x
USE CHARTS ATTACHED TO O.D. UNIT
Informowneron howtooperatesystemandwhat toexpectof it. Atthe sametimedeliverOwner'sUseand CareBooklet.
@ Also set thermostat dial to call for cooling or heating as necessary.
@ Check only necessary if heating unit is used for indoor section and wiring has been disturbed during installation of cooling equipment,
@ When applicable.