18-BC85D1-2
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service informa-
tion pack upon completion of work.
Heat Pumps
These instructions do not cover all variations in systems or provide for every possible contingency to be met in connection with
the installation. Should further information be desired or should particular problems arise which are not covered sufficiently for the
purchaser’s purposes, the matter should be referred to your installing dealer or local distributor.
Note: The manufacturer recommends installing only approved matched indoor and outdoor systems. All of the manufacture’s split
systems are AHRI rated only with TXV/EEV indoor systems. Some of the benefits of installing approved matched indoor and out-
door split systems are maximum efficiency, optimum performance and the best overall system reliability.
4TWB3018–060
Installer’s Guide
Table of Contents
Section 1. Safety ..................................................................................... 2
Section 2. Unit Location Considerations.............................................. 3
Section 3. Unit Preparation .................................................................... 5
Section 4. Setting the Unit ..................................................................... 5
Section 5. Refrigerant Line Considerations ......................................... 6
Section 6. Refrigerant Line Routing ..................................................... 7
Section 7. Refrigerant Line Brazing ...................................................... 8
Section 8. Refrigerant Line Leak Check .............................................10
Section 9. Evacuation ........................................................................... 11
Section 10. Service Valves ................................................................... 11
Section 11. Electrical - Low Voltage .................................................... 13
Section 12. Electrical - High Voltage ................................................... 16
Section 13. Start Up .............................................................................. 17
Section 14. System Charge Adjustment ............................................. 18
Section 15. Checkout Procedures and Troubleshooting ................... 23
Question and Answer IconNeed help?

Do you have a question about the Trane 4TWB3018D and is the answer not in the manual?

Trane 4TWB3018D Specifications

General IconGeneral
BrandTrane
Model4TWB3018D
CategoryHeat Pump
LanguageEnglish

Summary

Safety Precautions

Live Electrical Components Warning

Warning about potential danger when working with live electrical components during installation and servicing.

R-410A Refrigerant and Oil Handling

Guidelines for handling R-410A refrigerant, its higher pressures, and POE oil properties, including moisture absorption.

Refrigerant Line Management

Refrigerant Line Routing and Brazing

Refrigerant Line Brazing Procedure

Step-by-step instructions for brazing refrigerant lines to service valves with proper preparation.

Refrigerant Line Leak Check and Evacuation

Check For Leaks

Procedure for pressurizing lines with nitrogen and checking for leaks using a soapy solution.

Evacuate Refrigerant Lines and Indoor Coil

Steps for evacuating the system to a specified micron level for moisture removal.

Electrical - Low Voltage

Low Voltage Hook-up Diagrams

Wiring diagrams illustrating low voltage connections for various indoor units and thermostats.

Electrical - High Voltage

System Charge Adjustment

Subcooling Charging Above 55°F Outdoor

Procedure for subcooling charging in cooling mode when outdoor temperature is above 55°F.

Subcooling Charging Below 55°F Outdoor

Method for charging in heating mode when outdoor temperature is below 55°F.

Checkout and Troubleshooting

Operational and Checkout Procedures

Checklist for final inspection and operational verification after installation is complete.

Troubleshooting System Faults

Table identifying system faults, their causes, and recommended checks for refrigerant and electrical issues.