Do you have a question about the Trane 4TWX8036C and is the answer not in the manual?
Model | 4TWX8036C |
---|---|
Type | Heat Pump |
Cooling Capacity (BTU) | 36000 |
Cooling Capacity | 3 Tons |
Heating Capacity (BTU) | 36000 |
SEER Rating | Up to 18 |
HSPF Rating | Up to 9.5 |
Refrigerant | R-410A |
Voltage | 208-230 |
Phase | 1 |
Heating Capacity | 3 Tons |
Sound Level (dB) | 69 |
Sound Level (dBA) | 69 |
Compressor Type | ClimaTuff® Scroll Compressor |
Details the steps for preparing and brazing refrigerant lines, including cleaning and deburring.
Explains pressurizing lines with nitrogen and checking for leaks using soapy solution.
Guides on evacuating the system to a specific micron level and checking for rise.
Details the procedure for opening the gas service valve, including removing the cap and turning the stem.
Instructs on safely opening the liquid service valve, emphasizing caution with pressure.
Provides a step-by-step guide to starting the system, including thermostat settings and power application.
Details the subcooling method for charging in cooling mode when outdoor temp is above 55°F.
Explains the weigh-in method for charging in heating mode below 55°F outdoor temperature.
Provides a fault diagnosis chart for system issues, categorizing causes by refrigerant, electrical, and defrost.