Product Specifications
Heat Pump Models
OUTDOOR UNIT
(a)
A5HL5024A1 A5HL5036A1 A5HL5048A1 A5HL5060A1
POWER CONNS. – V/PH/HZ
(b)
208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60
MIN. BRCH. CIR. AMPACITY
20 25 35 35
MAX. OVER CURRENT PROTECTION
30 40 55 55
COMPRESSOR ROTARY ROTARY ROTARY ROTARY
NO. USED — NO. STAGES 1-MULTI 1-MULTI 1-MULTI 1-MULTI
VOLTS/PH/HZ 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60
R.L. AMPS
(c)
9.4 10.5 16.5 16.5
FACTORY INSTALLED
START COMPONENTS
(d)
No No No No
INSULATION/SOUND BLANKET
YES YES YES YES
COMPRESSOR HEAT YES YES YES YES
OUTDOOR FAN PROPELLER PROPELLER PROPELLER PROPELLER
DIA. (IN.) – NO. USED
21-5/8"-1 23-5/8"-1 20-7/8"-2 20-7/8"-2
TYPE DRIVE – NO. SPEEDS DIRECT-MULTI DIRECT-MULTI DIRECT-MULTI DIRECT-MULTI
NO. MOTORS – HP
1-1/8 1-1/4 2-1/8 2-1/8
CFM @ 0.0 IN. W.G.
(e)
2350 3000 4200 4200
MOTOR SPEED R.P.M. 200 — 1200 200 — 1200 200 — 1200 200 — 1200
VOLTS/PH/HZ 245–385/3/60 245–385/3/60 245–385/3/60 245–385/3/60
F.L. AMPS 1.1 2.1 1.45 1.45
OUTDOOR COIL – TYPE PLATE FIN™ PLATE FIN™ PLATE FIN™ PLATE FIN™
ROWS – F.P.I. 2-18 3-17 3-17 3-17
FACE AREA (SQ. FT.)
8.09 9.72 12.56 12.56
TUBE SIZE (IN.)
0.275" 0.275" 0.275" 0.275"
REFRIGERANT CONTROL
ELEC. EXPANSION
VALVE
ELEC. EXPANSION
VALVE
ELEC. EXPANSION
VALVE
ELEC. EXPANSION
VALVE
REFRIGERANT
LBS. – R-454B (O.D. UNIT)
(f)
5 lb – 5 oz 7 lb – 10 oz 8 lb — 13 oz 8 lb — 13 oz
FACTORY SUPPLIED YES YES YES YES
LINE SIZE – IN. O.D. GAS
3/4" 3/4" 7/8" 7/8"
LINE SIZE — IN. O.D. LIQ.
3/8" 3/8" 3/8" 3/8"
DIMENSIONS H X W X D H X W X D H X W X D H X W X D
CRATED (IN.)
36-11/16"x
40-1/4"x18-15/16"
38-3/16"x
44-11/16"x20-7/8"
57-3/8"x
42-17/32"x16-15/16"
57-3/8"x
42-17/32"x16-15/16"
UNCRATED (IN.)
31-11/32"x
38-1/2"x16-9/16"
33-25/32"x
42-1/2"x19-15/32"
52-11/16"x
40-23/32"x16-1/8"
52-11/16"x
40-23/32"x16-1/8"
WEIGHT
SHIPPING (LBS.)
146 192 260 260
NET (LBS.)
135 181 247 247
(a)
Certified in accordance with the Air-Source Unitary Air-conditioner Equipment certification program, which is based on AHRI standard 210/240.
(b)
Rated in accordance with AHRI standard 270/275.
(c)
Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses.
(d)
NA means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter.
(e)
This value approximate. For more precise value see unit nameplate.
(f)
The maximum length of refrigerant lines from outdoor to indoor varies depending on application. See Installer's Guide Table 4 for allowable applications.