Electrical Connections
Make wiring connections to the unit as indicated on enclosed wiring diagram. As with all gas appliances using electrical power, this furnace shall
be connected into a permanently live electric circuit. It is recommended that furnace be provided with a separate "circuit protection device"
electric circuit. The furnace must be electrically grounded in accordance with local codes or in the absence of local codes with the National
Electrical Code, ANSI/NFPA 70 , if an external electrical source is utilized. The integrated furnace control is polarity sensitive. The hot leg
of the 120V power supply must be connected to the black power lead as indicated on the wiring diagram.
Refer to the Wiring Diagram section in this document and unit wiring diagram attached to furnace.
WWAARRNNIINNGG
FFIIRREE HHAAZZAARRDD!!
FFaaiilluurree ttoo ffoollllooww tthhiiss WWaarrnniinngg ccoouulldd rreessuulltt iinn pprrooppeerrttyy ddaammaaggee,, sseevveerree ppeerrssoonnaall iinnjjuurryy,, oorr ddeeaatthh..
TThhiiss WWaarrnniinngg aapppplliieess ttoo iinnssttaallllaattiioonnss wwiitthh aa ffllaammmmaabbllee rreeffrriiggeerraattiioonn ssyysstteemm.. TThhee ffuurrnnaaccee mmuusstt bbee ppoowweerreedd
eexxcceepptt ffoorr sseerrvviiccee.. TThhee ffuurrnnaaccee sshhaallll bbee iinnssttaalllleedd aanndd ccoonnnneecctteedd aaccccoorrddiinngg ttoo iinnssttaallllaattiioonn iinnssttrruuccttiioonnss aanndd
wwiirriinngg ddiiaaggrraammss tthhaatt aarree pprroovviiddeedd wwiitthh tthhee eevvaappoorraattoorr ccooiill..
Field Wiring
Y1 Y1
B B
W1W1
GG
RR
Y1
Two Stage
Thermostat
Furnace
Outdoor Unit
(No Transformer)
R
X2
Y2
NOTES:
1) HP = Wiring used for Heat Pump systems.
2) Y1 and/or Y2 must connect from the thermostat to the IFC
for proper airflow.
3) A/TCONT824 thermostats do not require the use of X2.
HP
HP
FIELD WIRING DIAGRAM FOR A801X TWO STAGE
HEATING THERMOSTAT, ONE / TWO STAGE AC OR HEAT PUMP
B
Y2
Condensate
Switch
Option #1
Condensate
Switch
Condensate
Switch
Option #1
Condensate
Switch
Option #1
Option #2
Red
Blue
Black
Green
A/TFD Field Wiring
Using EAC Terminals
EAC
R
B
Replace the factory installed 35va transformer with the 50va transformer
supplied with the air cleaner. Connect to EAC terminals on the IFC per
the wiring diagram.