Installation
Operation &
Maintenance
WSHPC-IOM-2
72-9041-02
Library Service Literature
Product Section Unitary
Product Water Source Heat Pump
Model GSSD
Literature Type Installation, Operation and Maintenance
Sequence 2
Date June 1999
File No. SL-UN-WSHP-GSSD-IOM-2-6-99
Supersedes WSHPC-IOM-2 / 72-9041-01 (Jan 98)
Water Source Heat
Pump Residential
Split Configuration
HVAC System
©An American Standard Company
Since American Standard Inc. has a policy of continuous product improvement, it reserves the right to change specifications
and design without notice. The installation and servicing of the equipment referred in this booklet should be done by qualified,
experienced technicians.
Question and Answer IconNeed help?

Do you have a question about the Trane GSSD and is the answer not in the manual?

Summary

Model Number Breakdown

Product Type and Configuration

Explains digits 1-4 of the GSSD model number, covering product type and development sequence.

Unit Capacity and Electrical Specifications

Details unit nominal capacity (MBH) and voltage/hertz/phase configurations.

Unit Arrangement and Optional Features

Describes unit arrangement, design sequence, open digits, and desuperheater option.

General Unit Information

Unit Features and Construction

Covers brass loop connections, cabinet construction, and insulation.

Optional Desuperheater System

Explains the function, operation, and components of the optional desuperheater unit.

Compatible Thermostat Options

Lists suitable thermostat types for seamless unit operation.

Product Warranty Coverage

Outlines the manufacturer's warranty for unit parts and factory workmanship.

Unit Receiving and Handling Procedures

Shipping Inspection and Unpacking

Guides on inspecting packaged units for damage and safely removing shipping materials.

Installation Site Considerations

Unit Size 024 Dimensions and Weight

Provides dimensional drawings and weight specifications for Unit Size 024.

Unit Size 030-042 Dimensions and Weight

Provides dimensional drawings and weight specifications for Unit Sizes 030-042.

Unit Size 048-072 Dimensions and Weight

Provides dimensional drawings and weight specifications for Unit Sizes 048-072.

Water and Refrigerant Connections

Installation Location and Unit Access

Specifies required placement and methods for accessing the unit for service.

Water Hook-up Requirements

Details connection types and sizes for loop water and desuperheater hook-ups.

Refrigeration Piping Installation

Describes copper stub-outs, soldering, and insulation for refrigeration lines.

Electrical System Installation

Field Wiring and 24 V Control Wiring

Explains power and control wiring, including terminal identification and knockouts.

Electrical Component Overview

Details control box contents, component locations, and electrical data.

Pressure Switch and Freeze Protection

Explains the function of pressure switches and freezestats for system protection.

Unit Wiring Diagrams

Wiring Diagram Legend and Notes

Provides a legend for diagram components and important installation notes.

Water Loop System Design

Loop Water Application Types

Discusses geothermal vs. open loop systems and antifreeze requirements.

Open Loop System Considerations

Covers requirements for open loop systems, including straining and discharge.

Refrigerant Charge Procedures

R22 Charge for GSSD;TWE Systems

Lists R22 refrigerant quantities for GSSD units paired with TWE air handlers.

Refrigerant Charge for Connecting Lines

Provides R22 amounts for various tube sizes used in line sets.

System Charging and Superheat Measurement

Details steps for charging the system and achieving correct superheat levels.

Refrigeration System Components

Compressor and Heat Exchanger Details

Describes the high-efficiency scroll compressor and stainless steel heat exchanger.

Freeze Protection and Safety Lockout

Explains the function of freezestats and the lockout relay for safety.

Reversing Valve and Refrigerant Tubing

Details the reversing valve operation and insulated refrigerant tubing.

Optional Accessory Items

Water Regulating Valve Assembly

Describes the function and application of water regulating valve assemblies.

Motorized Water Valve for Open Loops

Explains the purpose of a motorized water valve in open loop systems.

Pump Modules and Hose Kits

Details pump modules and hose kits for closed loop geothermal systems.

Sand Filter;Separator Function

Explains the role of a sand filter/separator in maintaining water cleanliness.

Overview

This document describes the Installation, Operation, and Maintenance of the WSHPC-IOM-2 72-9041-02 Water Source Heat Pump Residential Split Configuration HVAC System, manufactured by American Standard Inc.

Function Description

The GSSD split unit is an ARI-rated water source heat pump designed for residential applications. It operates as a complete split system when coupled with Trane TWE air handlers equipped with ICM 2 variable speed motors. The unit is factory assembled, piped, internally wired, and test-operated, and is ETL and CSA listed. It is designed to provide efficient heating and cooling, with an optional desuperheater for domestic hot water preheating.

Important Technical Specifications

General:

  • Product Type: Ground Source Heat Pump (GS)
  • Configuration: Split System (S)
  • Development Sequence: D
  • Nominal Capacity (MBH): Available in 024 (24.1), 030 (29.6), 036 (36.4), 042 (41.1), 048 (48.7), 060 (59.2), and 072 (65.6) MBH.
  • Voltage/Hertz/Phase: 208/230-60-1
  • Unit Arrangement: Split Condensing Unit (0)
  • Design Sequence: C
  • Desuperheater: Available with (1) or without (0) desuperheater.
  • Freeze Protection: 35 Degree Freezestat (1) or 20 Degree Freezestat (2).
  • Brand: Command Aire (C) or Trane (T).

Physical Dimensions and Weight (Approximate):

  • Unit Size 024: 23" W x 23-5/16" H x 24-13/16" D, Weight: 163 lbs.
  • Unit Size 030-042: 23" W x 23-5/16" H x 24-13/16" D, Weights: 030 (169 lbs), 036 (183 lbs), 042 (203 lbs).
  • Unit Size 048-072: 23" W x 23-5/16" H x 24-13/16" D, Weights: 048 (214 lbs), 060 (244 lbs), 072 (277 lbs).

Connections:

  • System Water Inlet/Outlet: Female 1-inch NPT swivel quick connectors with stainless steel stop ring.
  • Desuperheater Connections (Optional): 1/2-inch NPT female water inlet and outlet.
  • Refrigeration Connections: Copper stub-outs, 3/4" O.D. (024) or 7/8" O.D. (030-072) for suction line, 1/2" O.D. for liquid line.
  • Electrical: Prewired terminal strip for 24V field control wiring. High voltage (1-1/8" DIA), Low voltage (1-1/8" DIA), Pump control (1-1/8" DIA).

Refrigerant (R22):

  • Charge for GSSD & TWE (without line connections):
    • GSSD024/TWE031E: 5.0 lbs
    • GSSD030/TWE031E: 5.0 lbs
    • GSSD036/TWE040E: 8.25 lbs
    • GSSD042/TWE040E: 9.25 lbs
    • GSSD048/TWE065E: 9.25 lbs
    • GSSD060/TWE065E: 10.125 lbs
    • GSSD072/TWE065E: 10.75 lbs
  • R22 Requirement per foot of line:
    • Liquid Line (oz.): 1/4" (0.352), 1/2" (1.152), 5/8" (1.840), 3/4" (4.272).
    • Suction Line (oz.): 1/2" (0.032), 5/8" (0.048), 3/4" (0.064), 7/8" (0.080), 1-1/8" (0.144).

Electrical Data (208/230V-60HZ/1Phase):

  • Compressor RLA: 11.4 (024) to 32.1 (072)
  • Compressor LRA: 56 (024) to 169 (060, 072)
  • Blower Motor RLA: 3 (024) to 7.4 (060, 072)
  • Min. Circuit Amp.: 14.7 (024) to 40.5 (072)
  • Max Fuse Size: 25 (024) to 70 (072)
  • Desuperheater Pump RLA: 0.40 (all models)
  • Operating Voltage Range: 197 to 253 volts.

Water Quality Requirements (for open loop systems):

  • Scaling (total hardness): Less than 350 ppm
  • Corrosion (pH): 7.5-9.5
  • Hydrogen Sulfide: Less than 1 ppm
  • Sulfates: Less than 25 ppm
  • Carbon dioxide: Less than 75 ppm
  • Chloride: Less than 125 ppm
  • Total dissolved solids (TDS): Less than 1000 ppm
  • Biological Growth (Iron bacteria): Low
  • Erosion (Suspended Solids): Low

Refrigeration System Components:

  • Compressor: High efficiency scroll compressor with internal vibration isolator and overload protection. External vibration isolation via rubber mounts.
  • Water-to-Refrigerant Heat Exchanger: High quality stainless steel braze plate heat exchanger, 450 psig working pressure rating.
  • Freezestat: 35°F for open loop/non-antifreeze closed loop, 20°F for closed loop with antifreeze.
  • Lockout Relay: Triggers shutdown of compressor, loop pumps, and desuperheater pump if safety devices (low pressure, high pressure, freezestat) are tripped.
  • Reversing Valve: Pilot operated sliding piston type with replaceable encapsulated magnetic coil. Energized in cooling, de-energized in heating.
  • Refrigerant Tubing: Copper, low temperature lines insulated with 3/8-inch thick elastomeric insulation (UL 94V-5 rated, flame spread rating < 25, smoke density rating < 50).
  • Refrigerant Metering: Bi-directional thermal expansion valve for operation with entering water temperatures from 25°F to 120°F.
  • Liquid Line Filter: Bi-directional liquid line filter drier.
  • Servicing Pressure Ports: High and low pressure Schrader ports located outside the unit case.

Usage Features

Installation:

  • Location: Must be placed on a level surface in an indoor protected area, with 2-3 feet clearance for service access. Not for exterior installation.
  • Water Connections: Uses 1-inch brass swivel connectors for loop water, eliminating need for backup wrench. Gaskets are provided. Desuperheater connections are 1/2-inch NPT.
  • Refrigeration Connections: Copper stub-outs, requiring soldering. Adapters may be needed for air handler connection. All refrigeration and water piping should be insulated.
  • Electrical: Power wiring per local codes. Control wiring is 24V. Prewired terminal strip for easy connection. Desuperheater fuse is shipped loose in the electrical compartment.
  • Thermostats: Compatible with single-stage manual changeover (Heat-Off-Cool, On-Off fan) or single-stage cool/two-stage heat manual changeover (Heat-Off-Cool, Auto/On fan, Normal-Auxiliary-Emergency Heat) thermostats, depending on whether electric backup heater is used.

Desuperheater (Optional):

  • Preheats domestic hot water using heat from the compressor discharge line.
  • Operates when discharge line reaches 145°F. Shuts off if incoming water exceeds 125°F to prevent overheating and pump damage.
  • Water cooled pump, requires connection to water heater before running.

Ground Water Applications (Open Loop):

  • Requires an ample supply of suitable quality water.
  • A 60 mesh straining device (sand filter/separator) is mandatory for incoming water line.
  • Discharge water must be returned to the aquifer via a recharge well.

Ground Water Applications (Closed Loop):

  • Loop sizing must be done by a qualified installer.
  • Requires at least 15% by volume antifreeze solution (propylene glycol or methanol) if ground water temperature is 66°F or less.
  • Only full strength inhibited propylene glycol or methanol should be used.

Refrigerant Charging:

  • Charge system to achieve 10 degrees superheat.
  • Sub-cooling should be approximately 8 to 5 degrees F.
  • Allow 20 minutes for conditions to stabilize before measuring superheat.
  • Return water flow to 3 gpm per nominal ton of capacity.
  • For non-TWE air handlers, place GSSD in cooling mode and throttle water flow until leaving fluid temperature is 95°F.

Maintenance Features

Access:

  • The top, front half of the diagonal cabinet is removable by removing two screws for access to internal components.

Safety Devices:

  • High and low pressure cutouts protect the compressor.
  • Freezestat protects the water heat exchanger from freezing.
  • All safety devices (except compressor internal overload) are connected to a lockout relay.

Troubleshooting:

  • Lockout Relay Reset: Can be reset by cycling power at the disconnect or thermostat system switch. If manually reset before a 5-minute period, the unit will not run.
  • Important Notice (Pressure Switch): The low pressure switch must be wired to activate at 35 psig for a 35°F freezestat, or 7 psig for a 20°F freezestat. Incorrect wiring can lead to unit failure and voided warranty.

Warranty:

  • Unit Warranty: One year for material and factory workmanship (labor and parts).
  • Refrigerant Circuit Warranty: Additional four years for compressor, expansion device, reversing valve (less solenoid coil), and heat exchangers (parts only).
  • Voided Warranty: Bypassing or removing any safety device voids the warranty.

Accessories (Purchased Separately):

  • Water Regulating Valve Assembly: Direct and reverse acting valves for low flow, or low/high fluid temperature conditions. Beneficial for open loop systems.
  • Motorized Water Valve: Installed on the return line of the system between the loop and pump module. Opens when compressor runs, slowly closes when compressor shuts down to prevent water hammer.
  • Electric Strip Heaters: ETL listed, install directly inside TWE air handler. Provide supplemental and emergency heat.
  • Pump Module: Self-contained pumping package for earth-coupled heat pump systems. Includes insulated Grundfos pumps, cabinet, optional cast iron/bronze pumps, 3-way brass valves. Available in one or two pump modules.
  • Hose Kits: Includes brass 1-inch male pipe thread (MPT) by barb-fittings, brass 90 degree 1-inch MPT by barb-elbows with pressure/temperature ports, and 10 feet of rubber hose with 4 hose clamps.
  • Sand Filter/Separator: Helps ensure clean water for the water-to-refrigerant heat exchanger. Recommended strainer is 60 mesh or greater.

Trane GSSD Specifications

General IconGeneral
BrandTrane
ModelGSSD
CategoryHeat Pump