OAU-SVX007A-EN 11
G = ERV – Aluminum Construction
with Bypass
H = ERV – Aluminum Construction
with Frost Protection and Bypass
Digit 32 — ERV Size
0 = No ERV
4 = 4634
5 = 5856
6 = 6488
7 = 6876
8 = 74122
Digit 33 — Damper Options
0 = 100% OA 2-Position Damper
1 = 100% OA 2-Position Damper
w/RA 2-Position Damper
2 = Modulating OA and RA Dampers
w/Economizer
3 = 100% OA 2-Position Damper –
Class 1A
4 = 100% OA 2-Position Damper w/RA
2-Position Damper – Class 1A
5 = Modulating OA and RA Dampers
w/Economizer – Class 1A
6 = 100% RA Opening (No Damper)
7 = 100% RA w/ 2-Position Damper
8 = 100% RA w/ 2-Position Damper –
Class 1A
Digit 34 — Filtration Options
A = Aluminum Mesh Intake Filters
(ALM)
B = MERV-8,30%, and ALM
C = MERV-13, 80%, and ALM
D = MERV-14, 95%, and ALM
E = MERV-8 30%, MERV-13 80%, and
ALM
F = MERV-8 30%, MERV-14 95%, and
ALM
G = MERV-8, 30%, and ALM, with UVC
H = MERV-13, 80%, and ALM, with
UVC
J = MERV-14, 95%, and ALM, with
UVC
K = MERV-8 30%, MERV-13 80%,
ALM, and UVC
L = MERV-8 30%, MERV-14 95%,
ALM, and UVC
X = Special Filter Options
Digit 35 — Smoke Detector (Factory-
Installed)
0 = No Smoke Detector
1 = Supply Smoke Detector
2 = Return Smoke Detector
3 = Supply and Return Smoke
Detectors
Digit 36 — Electrical Options
0 = Non-Fused Disconnect
A = Fused Disconnect Switch
B = Non-Fused Disconnect Switch
w/Convenience Outlet
C = Fused Disconnect Switch
w/Convenience Outlet
D = Dual Point Power
E = Dual Point Power
w/Convenience Outlet
F = 65 SCCR Electrical Rating
w/Non-Fused Disconnect
G = 65 SCCR Electrical Rating
w/Fused Disconnect
H = 65 KAIC Electrical Rating
w/Non-Fused Disconnect
J = 65 KAIC Electrical Rating
w/Fused Disconnect
K = 65 KAIC Non-Fused
w/Convenience Outlet
L = 65 KAIC Fused
w/Convenience Outlet
M = 65 SCCR Non-Fused
w/Convenience Outlet
Digit 37 — airflow Monitoring
0 = No Airflow Monitoring
1 = Airflow Monitoring – IFM
Piezo Ring
2 = Airflow Monitoring – PE
Piezo Ring
3 = Airflow Monitoring – Outdoor Air
with Display and IFM
w/Piezo Ring
4 = Airflow Monitoring – IFM
Piezo Ring and PE Piezo Ring
5 = Airflow Monitoring – Outdoor Air
Monitoring w/Display Supply Air
and Exhaust Air w/Piezo Rings
Digit 38 — Accessories
0 = No Options
A = Hailguards
B = LED Service Light
C = Hailguards and LED Service
Light
D = LED Service Light in
Exhaust Fan Section
E = LED Service Light in Supply
and Exhaust Fan Section
F = Hailguards and LED Service
Light in Exhaust Fan Section
G = Hailguards and LED Service
Light in Supply and
Exhaust Fan Section
Digit 39 — Altitude
0 = Sea Level to 1,000 Feet
1 = 1,001 to 2,000 Feet
2 = 2,001 to 3,000 Feet
3 = 3,001 to 4,000 Feet
4 = 4,001 to 5,000 Feet
5 = 5,001 to 6,000 Feet
6 = 6,001 to 7,000 Feet
7 = Above 7,000 Feet

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane Horizon OADG Series and is the answer not in the manual?

Trane Horizon OADG Series Specifications

General IconGeneral
BrandTrane
ModelHorizon OADG Series
CategoryHeat Pump
LanguageEnglish

Related product manuals