Model Number Descriptions
14 OAU-SVX007A-EN
Digit 39 — Exhaust Dampers
0 = No Exhaust Dampers
A = Gravity Dampers
B = Isolation Dampers
C = Barometric Relief Dampers
Digit 40 — Not Used
Digit 41 — Electrical Options
0 = Terminal Block – No Factory
Installed Disconnect
A = Non-Fused Disconnect
B = Fused Disconnect Switch
C = 65 SCCR Electrical Rating
w/Non-Fused Disconnect
D = 65 SCCR Electrical Rating
w/Fused Disconnect
E = 65 KAIC Electrical Rating
w/Non-Fused Disconnect
F = 65 KAIC Electrical Rating
w/Fused Disconnect
G = Dual Point Power
H = Dual Point Power 65 KAIC
J = Dual Point Power 65 SCCR
Digit 42 — Corrosive Environment
Package
0 = No Corrosive Package
A = Eco Coated Coils
B = S/S Interior
C = S/S Coil Casing
D = S/S Coil Casing with Eco Coated
Coils
E = S/S Interior, Eco Coated Coils
F = Corrosion Resistant Package
Digit 43 — Outdoor Air Monitoring
0 = No Outdoor Air Monitoring
1 = Airflow Probes
Digit 44 — Condenser Fan Options
0 = No Condenser Fans
A = Standard Condenser Fan
B = Passive Head Pressure Control
C = Active Head Pressure Control
D = ECM Condenser Fans with Active
Head Pressure Control
E = ECM Condenser Fans with Active
Head Pressure Control for Sound
Attenuation
Digit 45 — Compressor Sound
Blankets and Sound Attenuation
0 = No Sound Attenuation Package
A = Compressor Sound Blankets
B = Compressor Sound Blankets
with Sound Attenuation
Condenser Fans
Digit 46 — Smoke Detector
0 = No Smoke Detector
1 = Supply Smoke Detector
2 = Return Smoke Detector
3 = Supply and Return Smoke
Detector
4 = Supply Smoke Detector (Factory
Provided/Field Installed)
5 = Return Smoke Detector (Factory
Provided/Field Installed)
6 = Supply and Return Smoke
Detector (Factory Provided/Field
Installed)
Digit 47 — Hailguards
0 = No Hailguards
A = Hailguards
B = Outdoor Coil Wind Blockers
Digit 48 — Service Lights
0 = No Service Lights
A = Supply Fan Section Service Light
B = Exhaust Fan Section Service
Light
C = Supply and Exhaust Fan Section
Service Light
Digit 49 — UV Lights
0 = No UV Lights
1 = UV Lights
Digit 50 — Not Used
Digit 51 — Unit Installation Location
A = Outdoor
B = Indoor
Digit 52 — Convenience Outlet
0 = No Convenience Outlet
A = Convenience Outlet
Digit 53 — Controls Display
0 = No Display
1 = TD7 Factory Installed
2 = TD7 Remote Mounted
Digit 54 — Cooling Controls
0 = No ReliaTel™
A = ReliaTel™
B = ReliaTel™ with BCIR Card
Digit 55 — Face and Bypass on
Indoor Coil
0 = No Face and Bypass
Digit 56 — Thermostat
0 = No Thermostat
1 = Thumbwheel Thermostat
Digit 57 — Altitude
0 = Sea Level to 1000 Feet
1 = 1001 to 2000 Feet
2 = 2001 to 3000 Feet
3 = 3001 to 4000 Feet
4 = 4001 to 5000 Feet
5 = 5001 to 6000 Feet
6 = 6001 to 7000 Feet
7 = Above 7000 Feet
Digit 58 — Condensate Overflow
Switch
0 = No Condensate Overflow Switch
A = Condensate Overflow Switch
Digit 59 — Frostat
0 = No Frostat™
A = Frostat™ Installed
Digit 60 — Not Used
Digit 61 — Outdoor Coil Fluid Type
0 = None
1 = Water
2 = Ethylene Glycol
3 = Propylene Glycol
4 = Methanol
5 = Other
Digit 62 — Minimum Damper
Leakage
0 = Standard
1 = Class 1A
Digit 63, 64 — UC600 Hardware
Template
00 = Prior to Hardware Template
AA = v7.X
AB = v8.X
AC = v9.X
AD = v10.0
AE = v11.0 / Thrive v2.1
AF = v11.1 / Thrive v2.1
AG = v11.2 / Thrive v2.1
AH = v11.3 / Thrive v2.1
AK = v12.0 / Thrive v2.2
Digit 65, 66, 67, 68, 69 — Reserved
for Future Use

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane Horizon OADG Series and is the answer not in the manual?

Trane Horizon OADG Series Specifications

General IconGeneral
BrandTrane
ModelHorizon OADG Series
CategoryHeat Pump
LanguageEnglish

Related product manuals