Air Handler - Convertible
Models: Series 8 Air Handlers 2-5 Ton
HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING
WARNING:
HyperionFieldReferenceDataTAM8
For use with BAYEV or BAYW series heaters ONLY
WARNING
!
SAFETY HAZARD! This information is intended for use
by individuals possessing adequate backgrounds of electrical and
mechanical experience. Any attempt to repair a central air condition-
ing product may result in personal injury and/or property damage.
The manufacture or seller cannot be responsible for the interpreta-
tion of this information, nor can it assume any liability in connection
with its use.
PRESSURIZED REFRIGERANT! SYSTEM CONTAINS
OIL AND REFRIGERANT UNDER HIGH PRESSURE. RECOVER
REFRIGERANT TO RELIEVE PRESSURE BEFORE OPENING THE
SYSTEM.
DO NOT USE NON-APPROVED REFRIGERANTS OR REFRIGERANT
SUBSTITUTES OR REFRIGERANT ADDITIVES.
WARNING
!
LIVE ELECTRICAL COMPONENTS! During instal-
lation, testing, servicing, and troubleshooting of this product, it may
be necessary to work with live electrical components. Failure to fol-
low all electrical safety precautions when exposed to live electrical
components could result in death or serious injury.
WARNING
!
Note: This unit is certified to UL 1995.
The interior cabinet wall meets the following:
- UL94-5VA Flame Class Listed
- UL723 Steiner Tunnel Listed for 25/50 Flame/
Smoke
- UL746C Listed for Exposure to Ultraviolet Light,
Water Exposure and Immersion
NOTE: This unit as shipped is ONLY compatible with
Trane and American Standard communicating thermostats
and outdoor units. (24VAC thermostats cannot be used)
With the addition of a BAYCC24VK01 accessory, this unit
can be compatible with a 24VAC single or multistage heat
pump or air conditioner.
Table of Contents
Product Specifications. .................................................................................................... 2
Wiring Diagram. ............................................................................................................... 3
Sequence of Operation. ................................................................................................... 4
Control Layout - Refrigerant Dip Switch .......................................................................... 6
Airflow Performance. ........................................................................................................ 7
Heater Attribute Data. .................................................................................................... 13
Control Layout - LEDs. ................................................................................................... 16
Alert Codes. ................................................................................................................... 22
EEV Test Procedures. .................................................................................................... 23
EVC Thermal Resistance and Voltage Table. ................................................................ 24
AFC Supply Air Temperature Sensor Table. ................................................................... 25
Display Assembly Menus. .............................................................................................. 26
Troubleshooting. ............................................................................................................ 32
*AM8A0A24V21CA, *AM8A0B30V21CA
*AM8A0C36V31CA, *AM8A0C42V31CA
*AM8A0C48V41CA, *AM8A0C60V51CA
* May be "A" or "T"
Question and Answer IconNeed help?

Do you have a question about the Trane Hyperion TAM8A0C48V41CA and is the answer not in the manual?

Trane Hyperion TAM8A0C48V41CA Specifications

General IconGeneral
BrandTrane
ModelHyperion TAM8A0C48V41CA
CategoryAir Handlers
LanguageEnglish

Summary

General Safety Warnings

Hazardous Voltage and Electrical Safety

Warnings regarding live electrical components and high voltage hazards during servicing.

Pressurized Refrigerant and System Safety

Precautions for handling systems under high pressure and refrigerant safety.

General Safety Hazard Information

Intended for qualified individuals; manufacturer not responsible for interpretation.

Wiring Diagram and Electrical Precautions

Wiring Diagram for Air Handlers

Visual representation of electrical connections for the AM8 air handlers.

Electrical Safety and Conductor Guidelines

Warnings about hazardous voltage and using only copper conductors.

Fault Reporting and System Controls

Control Panel Status Indicators

Alert Codes and Troubleshooting Reference

Electronic Expansion Valve (EEV) Test Procedures

EEV Test Option 1: Unit Menu Access

Accessing EEV tests through the Display Assembly's Unit Test option.

EEV Test Option 2: Pin Test Procedures

Performing Close Valve and Open Valve tests using specific pins on the EVC board.

Display Assembly Interface and Navigation

Technician Monitor Menu

Technician Alert Menu

Technician Configuration Menu

Technician Control Menu

General Troubleshooting Procedures

Sensor Check and Verification

Flowchart for checking sensor connections, voltage, and resistance.

High Superheat Troubleshooting Guide

Low Superheat Troubleshooting Guide