42
L8V1-SVX001-1A-EN
Integrated Furnace Control Menu
Status Menu
Acve Errors
Example
1 Stage Gas Heat
Example
800 CFM
Last 6 Faults
Example
Open Limit Switch
Error
Control Release #
Example
Soware Version #
Cooling Off Delay
Example
seconds
Example
Enhanced Mode
Outdoor Tonnage
Example
Outdoor Nominal Tonnage
OD Unit Type
Example
Connuous Fan
Example
50% Cooling Airflow
Cooling CFM
per Ton
Example
CFM per Ton
Heat Off Delay
Example
Seconds
Inter-Stage Delay
Example
Seconds
Gas Heang CFM
Example
2
nd
stage Heang CFM
L8V1
Control System Menu
Example
2 stage 1 compressor
Example
2 stage 2 compressor
CLEARING THE LAST6 FAULTS:
To clear the stored faults, scroll to the last 6 faults
menu (LF6), enter the menu by scrolling to the right
and hold the “OPTION” key for at least 5 seconds.
Release and a set of 3 dashes will be seen 3 mes.
This confirms the faults have been cleared.
SETTING UP YOUR SYSTEM:
To change any factory default value, first remove any “call”
from the furnace and allow any fan off delays to finish. (
should be seen on the display.)
Scroll to the selected Menu item by momentarily depressing
the “MENU” key and then depress the “OPTION” key to the
desired seng. Then momentarily depress the “MENU” key
again to save the change.
CFM per Ton selecons range from 290 – 450
Important:
When applied with zoning or a VSPD outdoor unit,
the CFM/Ton must be set to 400 and ODT must
match the OD tonnage.
Gas heang CFM can be adjusted while the unit is
operang in gas heat mode to enable the technician to
quickly adjust to the manufacturer's suggested heat
rise across the heat exchanger.
Mulply the value shown by 10 for actual airflow.
Model Gas Heang CFM [ ]=Default
Upflow
L8V1A040U3VS 061[061], 063, 070, 055
Model ODT Opons [ ]= Default
Upflow
Heang CFM
per Ton
Example
CFM per Ton
Run Test Mode
See Run Test Menu
L8V1A040U3VS 3T[3T], 1.5T, 2T, 2.5T
Example
2ⁿ Stage Pressure Switch Error
Exam
pl
e
1 Stage Pressure Switch Error
E3_4
E3_1
E04
E3_4 E3_1
Example
2ⁿ Stage Pressure Switch Error
Example
1 Stage Pressure Switch Error
021
1_5
1-1 2-1
2-2
1 stage 1 compressor
50
75 100 25
370
400
370
400
140
180 60
099
083 096
L8V1A060U3VS 3T[3T], 1.5T, 2T, 2.5T
L8V1B080U4VS 4T[4T], 2T, 2.5T, 3T, 3.5T
L8V1C100U5VS 5T[5T], 2.5T, 3T, 3.5T, 4T, 4.5T
Note:
Do not adjust COF above 50%.
L8V1C100U5VS 150[150], 160, 190, 200
L8V1B080U4VS 135[135], 140, 118, 125
L8V1A060U3VS 099[099], 113, 083, 096

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane L8V1A040U3VSBA and is the answer not in the manual?

Trane L8V1A040U3VSBA Specifications

General IconGeneral
BrandTrane
ModelL8V1A040U3VSBA
CategoryFurnace
LanguageEnglish

Related product manuals