21
Gas Piping
Important: The furnace default is left side gas piping.
Note: For ease of installation, optional accessory part PIP02095 is
recommended for gas piping entering the right side of the
furnace.
Furnace in upflow orientation with gas piping on left
Main Manual
Shut-o Valve
Ground
Union
Joint
Drip Leg
1/8” NPT
Test Fitting
Automatic Gas Valve
with Manual Shut-o
Furnace in upflow orientation with gas piping on right
Note: For ease of installation, optional accessory part PIP02095 is
recommended for gas piping entering the right side of the
furnace in the upflow orientation.
Automatic Gas Valve
with Manual Shut-o
Main Manual
Shut-o Valve
Ground
Union
Joint
Drip Leg
1/8” NPT
Test Fitting
Note: For ease of installation, optional accessory part PIP02095 is
recommended for gas piping entering the right side of the
furnace.
Furnace in horizontal left orientation with gas piping out top
Note: For ease of installation, optional accessory part PIP02095 is
recommended for gas piping entering the top of the furnace in
the horizontal left position.
Main Manual
Shut-o Valve
Ground
Union
Joint
Drip Leg
1/8” NPT
Test Fitting
Automatic Gas Valve
with Manual Shut-o
Furnace in horizontal left orientation with gas piping out bottom
FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn