PKGP-SVX010A-EN
Model Number Description
Digit 1 Unit Function
W = Packaged Heat Pump
Digit 2 Cooling Efficiency
S = Standard Efficiency
Digit 3 Refrigerant
J = R-410A
Digit 4,5,6 Nominal Gross Cooling
Capacity (MBh)
150 = 12.5 Ton
180 = 15 Ton
240 = 20 Ton
300 = 25 Ton
Digit 7 Design Sequence
Digit 8 Voltage Selection
3 = 208–230/60/3
4 = 460/60/3
W = 575/60/3
Digit 9 Unit Controls
S = Symbio™ 700
Digit 10 Heat Type
0 = Base Model (None or Electric)
Digit 11 Heating Capacity
1
0 = No Heat
G = 18 kW Electric Heat
K = 27 kW Electric Heat
N = 36 kW Electric Heat
P = 54 kW Electric Heat
R = 72 kW Electric Heat
Digit 12, 13 Service Sequence
** = Factory Assigned
Digit 14 Fresh Air Selection
0 = No Fresh Air
A = Manual Outside Air Damper 0–50%
B = Motorized Outside Air Damper 0–50%
C = Economizer, Dry Bulb 0–100% without
Barometric Relief
2
D = Economizer, Dry Bulb 0–100% with
Barometric Relief
2
E = Economizer, Reference Enthalpy 0–100%
without Barometric Relief
2
F = Economizer, Reference Enthalpy 0–100%
with Barometric Relief
2
G = Economizer, Comparative Enthalpy
0–100% without Barometric Relief
2
H = Economizer, Comparative Enthalpy
0–100% with Barometric Relief
2
K = Downflow Low Leak Economizer, Dry Bulb
with Barometric Relief
2
M = Downflow Low Leak Economizer, Reference
Enthalpy with Barometric Relief
2
P = Downflow Low Leak Economizer,
Comparative Enthalpy with Barometric Relief
2
R= Downflow Low Leak Economizer, Differential
Dry Bulb with Barometric Relief
2
Digit 15 Supply Fan/Motor
0 = Multi-Speed Motor
1 = Optional Oversized/High Static Motor
2 = Single Zone Variable Air Volume with
Standard Motor
3 = Single Zone Variable Air Volume with
Oversized/High Static Motor
4 = Multiple Zone Variable Air Volume with
Standard Motor
5 = Multiple Zone Variable Air Volume with
Oversized/High Static Motor
Digit 16 Hinged Access/Filters
0 = Standard Panels/Standard Filters
A = Hinged Access Panels/Standard Filters
B = Standard Panels/2 inch MERV 8 Filters
C = Hinged Access Panels/2 inch MERV 8 Filters
D = Standard Panels/2 inch MERV 13 Filters
E = Hinged Access Panels/2 inch MERV 13 Filters
Digit 17 Coil Protection
0 = Standard Coil
Digit 18 Through-the-Base Provisions
0 = No Through-the-Base Provisions
A = Through-the-Base Electric
Digit 19 Disconnect/Circuit Breaker (three-
phase only)
0 = No Disconnect/No Circuit Breaker
1 = Unit Mounted/Non-Fused Disconnect
2 = Unit Mounted Circuit Breaker
Digit 20— Convenience Outlet
0 = No Convenience Outlet
A = Unpowered 20A Convenience Outlet
B = Powered 15A Convenience Outlet
(three-phase only)
Digit 21— Communications Options
0 = No Communications Interface
1 = Advanced Controller with BACnet®
Communications Interface
2 = Advanced Controller with LonTalk®
Communications Interface
3 = Advanced Controller with Air-Fi®
Communications Interface
Digit 22— Refrigeration System Option
0 = Standard Refrigeration System
A = Dehumidification Option
1
,
3
Digit 23— Controls Expansion Module
0 = None
1 = XM-30 Expansion Module
2 = XM-32 Expansion Module
3 = XM-30 and XM-32 Expansion Module
4 = XM–30 Expansion Module (Qty 2)
5 = XM–32 Expansion Module (Qty 2)
Digit 24— Smoke Detector
0 = No Smoke Detector
A = Return Air Smoke Detector
2
B = Supply Air Smoke Detector
1
C = Supply and Return Air Smoke Detectors
1
,