58
S8XB-SVX001-1B-EN
e6.2
Bad grounding
e6.3
(1) Igniter relay fails
(2) Igniter open
e7.!
1st stage gas valve (MVL) is energized when it should be off
e08
Flame current is low, but still strong enough to allow operation
e11
(1) 1st stage gas valve not energized when it should be
(2) 1st stage gas valve relay stuck closed
(3) 2nd stage gas valve relay stuck closed (Not Applicable for S8B1, S8X1)
(4) 2nd stage gas valve energized when it should not be (Not Applicable for S8B1, S8X1)
(5) 2nd stage gas valve not energized when it should be (Not Applicable for S8B1, S8X1)
e12
Open fuse