Do you have a question about the Trane S8X2A040M3PSC and is the answer not in the manual?
Model | S8X2A040M3PSC |
---|---|
Type | Gas Furnace |
Heating Capacity | 40, 000 BTU |
Efficiency Rating | 80% AFUE |
Blower Motor | PSC |
Fuel Type | Natural Gas |
Ignition Type | Hot Surface Ignition |
Weight | 120 lbs |
Warranty | 10-Year Limited |
Dimensions (H x W x D) | 17.5 |
Stages | Single-Stage |
Potential for fire or explosion if safety warnings are not followed.
Warning about electrical hazards, fire, and explosion.
Risk of carbon monoxide poisoning due to improper venting.
Warning regarding explosion hazards and gas leaks.
Caution about electrical shock risks during servicing.
General safety hazard warning.
Warning about hazards from high voltage and moving parts during installation.
Specific warning about electrical shock hazards.
Procedures for recovering from furnace fault codes.
List of error codes and their explanations.
Troubleshooting flow for fault code E01 (Internal failure).
Troubleshooting flow for fault code 2.1 (Flame not sensed).
Troubleshooting flow for fault code 2.2 (Flame lost after sensed).
Troubleshooting flow for fault code 2.3 (1st Stage Gas Valve not energized).
Troubleshooting flow for fault code 3.1 (PS1 closed when open).
Troubleshooting flow for fault code 3.2 (PS1 open when closed).
Troubleshooting flow for fault code 3.3 (PS2 closed when open).
Troubleshooting flow for fault code 3.4 (PS2 open when closed).
Troubleshooting flow for fault code 4.0 (Limit switches).
Troubleshooting flow for fault code 5.0 (Flame sensed when not expected).
Troubleshooting flow for fault code 6.1 (Polarity fault).
Troubleshooting flow for fault code 6.2 (Ground fault).
Troubleshooting flow for fault code 6.3 (Igniter fault).
Troubleshooting flow for fault code 7.1 (External gas valve circuit error).
Troubleshooting flow for fault code 08 (Flame sense current low).
Troubleshooting flow for fault code 11 (Gas valve relay failure).
Troubleshooting flow for fault code 12 (Onboard fuse issue).