4. Make connections per hookup diagrams.
Scan to see a
video on Field
Wirin g the TAM7
Figure 1. Field Wiring Single Stage Cooling
Comfort Control
Air Handler
Air Conditioner
Neatly bundl e all low voltage
wires behin d the service
valve cover as shown.
Field wiring
Yellow
Blue
Red
Yellow
Green
White
Blue
B
B - Blue
W
G
Y1
Y2
Y1 - Yellow
R
O
O
R
B
YI
W1
YO
Y2
BK
G
W2
W3 *
(In)
(Out)
* For multiple stages of electric heat, jumper W1, W2, and W3 together if control has only one stage of heat.
Yi and Y0 connections must be made as shown for freeze protection and internally mounted condensate overflow circuits to work properly.
OD unit pump down may occur if these connections are not made correctly.
Internally mounted condensate switch is optional and must be ordered separately.
If 3rd party condensate overflow switches are installed, they should be wired between Y of the thermostat and Y1 of the Airflow control.