ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
Installer’s Guide
TCONT200AN11AA
1 Heat (Gas, Oil* or Elec) / 1 Cool
Electronic Non-Programmable, 4 Wire Hookup
XB200 Comfort Control
Introduction
TCONT200AN11AA is a digital non-programmable 1Heat/1
Cool wall mounted low voltage (24Vac) Comfort Control with
backlit LCD and keypad. It maintains room temperature by
controlling the operation of heating and cooling systems. The
XB Comfort Control is easily configured for Heating Only
(gas or electric) or Cooling Only applications via the user
friendly Installer Setup menu. The XB Comfort Control
features separate heating and cooling setpoints, selectable
Auto or Manual Changeover, adjustable Energy Saving
mode, adjustable filter reminder and LitePort technology for
extended system diagnostics and fault notification. Setup
selections and diagnostics are stored indefinitely in the XB
Comfort Controls nonvolatile memory eliminating the need
for battery backup.
Safety Considerations
Read the following manufacturer instructions carefully.
Follow all local codes during installation. All wiring must
conform to local and national electrical codes. Improper
wiring or installation may damage comfort control.
Recognize safety information. This is the safety alert symbol
!
. When you see this symbol on the equipment and in the
instruction manual, be alert to the potential for personal
injury.
Understand the signal words DANGER, WARNING and
CAUTION. These words are used with the safety-alert
symbol. DANGER indentifies the most serious hazards which
will result in severe personal injury or death. WARNING
signifies a hazard which could result in personal injury or
death. CAUTION is used to identify unsafe practices which
could result in minor personal injury or product and prop-
erty damage.
Note: Read the entire instruction manual before starting the
installation.
Application Hook-up diagrams FIG
1 Heat / 1 Cool (Gas or Electric) Fig. 3, 4, & 5
1 Heat / 0 Cool (Gas or Electric) Fig. 6
0 Heat / 1 Cool Fig. 5
1 Heat / 1 Cool (Oil Furnace) Fig. 7
1 Heat / 0 Cool (Oil Furnace) Fig. 8
SYSTEM MODE: HEAT, COOL, AUTO and OFF
FAN MODE: AUTO or ON
* Requires external relay for Oil furnace applications.
Product Specifications
- Power Source: 20V-30VAC, 50/60Hz, Load Powered
through W and Y.
- Cooling setpoint temperature range: 65F - 90F,
18.0C - 33.0C, 1F and 0.5C resolution.
- Heating setpoint temperature range: 40F- 85F,
5.0C - 30.0C, 1F and 0.5C resolution.
- Default set points: 68F, 20.0C Heat, 78F, 25.5C Cool
- Storage Range: -40F to 140F, 5% - 90% RH non-
condensing.
- Operating Temperature range: 32F - 110F, 5 - 90% RH
non-condensing.
- Minimum Cycle Off Time Delay: Cooling - 5 minutes,
Heating - 1 minute.
- Use minimum 18 gauge NEC approved control
wiring.
$
FAN MODEFILTER
Contents
Introduction ........................................................................ 1
Application .......................................................................... 1
Product Specifications ...................................................... 1
Installation .......................................................................... 2
Mounting and Wiring .......................................................... 2
SETUP ................................................................................. 4
Checkout ............................................................................. 4
Troubleshooting .................................................................. 6
Features .............................................................................. 7
18-HD29D1-3
Available in French Canadian (FC)
CAUTION
!
To prevent shortening its service life, the control should not
be installed until construction is completed.
© 2008 Trane
Question and Answer IconNeed help?

Do you have a question about the Trane TCONT200AN11AA and is the answer not in the manual?

Overview

The Trane XB200 Comfort Control (TCONT200AN11AA) is a digital non-programmable thermostat designed for wall-mounted, low-voltage (24Vac) heating and cooling systems. It supports 1 Heat (Gas, Oil, or Electric) and 1 Cool applications, featuring a 4-wire hookup. This control maintains room temperature by managing the operation of HVAC systems and is easily configured for various heating or cooling only applications via its user-friendly Installer Setup menu.

Function Description:

The primary function of the XB200 Comfort Control is to regulate indoor temperature. It allows users to set desired heating and cooling setpoints, and it controls the HVAC equipment to achieve and maintain these temperatures. The control offers both Auto and Manual Changeover modes, enabling it to automatically switch between heating and cooling as needed or to be manually set to a specific mode. It incorporates LitePort technology for extended system diagnostics and fault notification, which can be crucial for troubleshooting and maintenance. All setup selections and diagnostic data are stored in nonvolatile memory, eliminating the need for battery backup.

Important Technical Specifications:

  • Power Source: 20V-30VAC, 50/60Hz, with the load powered through W and Y terminals.
  • Cooling Setpoint Temperature Range: 65°F - 90°F (18.0°C - 33.0°C), with 1°F (0.5°C) resolution.
  • Heating Setpoint Temperature Range: 40°F - 85°F (5.0°C - 30.0°C), with 1°F (0.5°C) resolution.
  • Default Setpoints: 68°F (20.0°C) for Heat, 78°F (25.5°C) for Cool.
  • Storage Range: -40°F to 140°F (-40°C to 60°C), 5% - 90% RH non-condensing.
  • Operating Temperature Range: 32°F - 110°F (0°C to 43°C), 5% - 90% RH non-condensing.
  • Minimum Cycle Off Time Delay: Cooling - 5 minutes, Heating - 1 minute.
  • Wiring: Requires minimum 18 gauge NEC approved control wiring.
  • Resistors: Two 360 ohm (5 watts) resistors are included. One must be installed between the "W" and "B/C" terminals of the indoor unit low voltage terminal block. The second resistor is required between "Y" and "B/C" at the indoor unit low voltage terminal block if no outdoor unit is installed or if the outdoor unit has a compressor anti-short cycle timer installed.

Usage Features:

  • Backlit LCD and Keypad: Improves visibility, especially in low-light conditions. The backlight stays on for 10 seconds after the last key press.
  • Separate Heating and Cooling Setpoints: Allows for precise temperature control for both modes.
  • Auto or Manual Changeover: Provides flexibility in how the system switches between heating and cooling.
  • Energy Savings Mode: Offsets the indoor setpoint to a cooler temperature for heating and a warmer temperature for cooling, activated by the "$" key. This feature provides instant energy savings.
  • Cooling Droop: An automatic function that cycles the compressor to improve indoor comfort by removing moisture from the air. It activates when the temperature is at or below the cooling setpoint and controls temperature 1 or 2 degrees below the setpoint.
  • Keypad Lock: Prevents unwanted tampering or changes to thermostat settings by locking the keypad. Activated by pressing and holding the Up and Down arrow buttons simultaneously for 2 seconds.
  • Installer Setup Menu (ISU) and User Setup Menu (USU): Provides comprehensive configuration options for installers and basic settings for users.
  • Manual Test Mode: Allows installers to quickly and easily test individual control outputs and perform diagnostic procedures without damaging the compressor.
  • Control Response Rate: Adjustable to "Normal" or "Fast" to increase the responsiveness of temperature control performance.
  • Calibrate Indoor Temperature: Allows for calibration of the room temperature sensor by adding or subtracting up to 5 degrees in 0.5-degree increments.
  • Waiting Indicator: Illuminates when system time delays are being enforced or when the control is adjusting to new settings.

Maintenance Features:

  • Filter Reminder: The "FILTER" icon flashes automatically to remind the homeowner to change the filter. Pressing the "Filter" button resets the internal clock timer.
  • LitePort Technology: A patented feature that provides service technicians access to extended real-time and historical data events stored in the thermostat's memory, aiding in diagnostics and fault notification.
  • Service Indicator: The "SERVICE" indicator automatically flashes when an internal fault or error is detected by the thermostat, prompting for a check of setup choices.
  • Business Card Drawer: A convenient slot on the mounting base for inserting a business card, allowing homeowners to easily locate their local servicer's contact information.
  • Nonvolatile Memory: Stores all setup selections and diagnostics indefinitely, eliminating the need for battery replacement and ensuring settings are retained even during power outages.
  • Minimum Off Time Delay Override: Allows for overriding minimum off-time delays for the current cycle by pressing the Mode and Down arrow keys simultaneously, useful for testing or immediate adjustments.

Trane TCONT200AN11AA Specifications

General IconGeneral
BrandTrane
ModelTCONT200AN11AA
CategoryThermostat
LanguageEnglish