Par.
No. #
Parameter description Default value 2-set-up Change
during
operation
Conversion
index
Type
5-90 Digital & Relay Bus Control 0 N/A All set-ups FALSE 0 Uint32
5.1.8 6-** Analog In/Out
Par.
No. #
Parameter description Default value 2-set-up Change
during
operation
Conversion
index
Type
6-0* Analog I/O Mode
6-00 Live Zero Timeout Time 10 s All set-ups FALSE 0 Uint8
6-01 Live Zero Timeout Function [0] O All set-ups FALSE Uint8
6-02 Fire Mode Live Zero Timeout Function [0] O All set-ups FALSE Uint8
6-1* Analog Input 53
6-10 Terminal 53 Low Voltage 0.07 V All set-ups FALSE -2 Uint16
6-11 Terminal 53 High Voltage 10 V All set-ups FALSE -2 Uint16
6-12 Terminal 53 Low Current 4 mA All set-ups FALSE -5 Uint16
6-13 Terminal 53 High Current 20 mA All set-ups FALSE -5 Uint16
6-14 Terminal 53 Low Ref./Feedb. Value 0 N/A All set-ups FALSE -3 Int32
6-15 Terminal 53 High Ref./Feedb. Value ExpressionLimit All set-ups FALSE -3 Int32
6-16 Terminal 53 Filter Time Constant 0.01 s All set-ups FALSE -2 Uint16
6-19 Terminal 53 mode [1] Voltage mode 1 set-up FALSE - Uint8
6-2* Analog Input 54
6-20 Terminal 54 Low Voltage 0.07 V All set-ups FALSE -2 Uint16
6-21 Terminal 54 High Voltage 10 V All set-ups FALSE -2 Uint16
6-22 Terminal 54 Low Current 4 mA All set-ups FALSE -5 Uint16
6-23 Terminal 54 High Current 20 mA All set-ups FALSE -5 Uint16
6-24 Terminal 54 Low Ref./Feedb. Value 0 N/A All set-ups FALSE -3 Int32
6-25 Terminal 54 High Ref./Feedb. Value ExpressionLimit All set-ups FALSE -3 Int32
6-26 Terminal 54 Filter Time Constant 0.01 s All set-ups FALSE -2 Uint16
6-29 Terminal 54 mode [1] Voltage mode 1 set-up FALSE Uint8
6-7* Analog/Digital Output 45
6-70 Terminal 45 Mode [0] 0-20 mA All set-ups FALSE Uint8
6-71 Terminal 45 Analog Output [0] No operation All set-ups FALSE Uint8
6-72 Terminal 45 Digital Output [0] No operation All set-ups FALSE Uint8
6-73 Terminal 45 Output Min Scale 0% All set-ups FALSE -2 Uint16
6-74 Terminal 45 Output Max Scale 100% All set-ups FALSE -2 Uint16
6-76 Terminal 45 Output Bus Control 0 N/A All set-ups FALSE 0 Uint16
6-9* Analog/Digital Output 42
6-90 Terminal 42 Mode [0] 0-20 mA All set-ups FALSE Uint8
6-91 Terminal 42 Analog Output [0] No operation All set-ups FALSE Uint8
6-92 Terminal 42 Digital Output [0] No operation All set-ups FALSE Uint8
6-93 Terminal 42 Output Min Scale 0% All set-ups FALSE -2 Uint16
6-94 Terminal 42 Output Max Scale 100% All set-ups FALSE -2 Uint16
6-96 Terminal 42 Output Bus Control 0 N/A All set-ups FALSE 0 Uint16
Parameter Lists TR150 and TR170
108 02/2017 All rights reserved. BAS-SVP16B-EN