October 2009
SS-APG008-EN
Tube Size and Component
Selection
for TTA and TWA Split Systems (6-20 Tons)
Using Refrigerant 410A
Model Numbers:
TTA073D TTA090D TTA120D
TTA120E TTA120F TTA150E
TTA180E TTA180F TTA240E
TTA240F TWA073D TWA120D
TWA180E TWA240E TWA090
Application Guide
Question and Answer IconNeed help?

Do you have a question about the Trane TTA073D and is the answer not in the manual?

Trane TTA073D Specifications

General IconGeneral
ModelTTA073D
Cooling Capacity73000 BTU/H
RefrigerantR-410A
Compressor TypeScroll
Voltage208/230V

Summary

Warnings, Cautions and Notices

Environmental Concerns

Discusses the impact of chemicals on the ozone layer.

Responsible Refrigerant Practices

Emphasizes technician certification and legal compliance.

Personal Protective Equipment (PPE) Required

Details mandatory PPE for installation and servicing.

Introduction to the Application Guide

System Overview and Application

Describes the TTA/TWA units and their intended operating envelope.

System Overview and Principles

Background of Refrigerant Piping

Explains the historical principles guiding refrigerant piping practices.

Updated Refrigerant Piping Guidelines

Details changes for R-410A pressure and oil entrainment.

Equipment Placement Considerations

Focuses on minimizing distance between system components.

Line Sizing, Routing, and Component Selection

Liquid Lines

Covers sizing, routing, insulation, and components for liquid lines.

Gas Line Considerations

Covers sizing, routing, insulation, and components for gas lines.

Expansion Valves

Details selection, types, and adjustment of expansion valves.

System Controls

Discusses system controls and compressor staging for stability.

Hot Gas Bypass (HGBP)

Explains HGBP, its drawbacks, and alternative EDC systems.

Remodel, Retrofit, and Replacement

R-410A System Conversion Guidelines

Details compatibility checks and component requirements for upgrading to R-410A.

Refrigerant Piping Examples

TTA Cooling-Only Unit Examples

Illustrates piping arrangements for TTA units with indoor coils.

TWA Heat Pump Examples

Illustrates piping arrangements for TWA heat pumps.

Parts and Component Selection

TTA Component Selection Summary

Lists components and line sizes for TTA models.

TWA Component Selection Summary

Lists components and line sizes for TWA models.