Installation Manual
Mini-Split System
Condensing Units TTK
Horizontal Air Discharge
9,000 to 36,000 BTU/h
50/60 Hz
SS-SVN03B-EN
September 2003
Models:
TTK 509 E TTK 518 E
TTK 512 E TTK 524 E
TTK 530 E
TTK 536 E
Question and Answer IconNeed help?

Do you have a question about the Trane TTK 509 E and is the answer not in the manual?

Summary

General Information

General System Overview

Describes the Trane mini-split system, quality standards, and the purpose of the installation manual.

About This Manual

Discusses cautions, safety, and the manual's scope for installing the air conditioning system.

About This Unit

Describes the TTK condensing units, their capacity range, and operational modes.

Unit Reception Procedures

Instructions for inspecting the unit upon arrival and reporting any transit damage.

Warranty Information

Details on warranty terms, conditions, and what voids the warranty.

Important Installation Notes

Notes regarding customer property, seeking further information, and installation responsibility.

Model Number Breakdown

Model Number Explanation

Explains the 11-digit model number structure and the meaning of each digit.

General Data

General Information and Scope

Overview of the manual's scope for TTK units and general installation guidelines.

Unit Location and Preparation

Guidelines for selecting and preparing the installation site, including clearances.

Line Connections

Refrigerant Line Connections

Covers flange thread-type connections for TTK series refrigerant lines.

Connecting Refrigerant Lines

Step-by-step guide for using flange thread-type service valves for line connections.

System Evacuation

System Evacuation and Purge

Details the process of evacuating and purging the refrigerant lines and indoor unit.

Service Valve

Multi-Function Liquid Line Service Valve Installation

Covers the field installation of the restrictor for the multi-function service valve on the liquid line.

Electric Connections

Electric Connection Procedures

Details wiring, grounding, power supply, circuit breaker requirements, and wire color usage.

System Start-Up

System Checking Before Start-Up

Outlines pre-operation checks for refrigerant, electrical connections, and unit integrity.

Dimensional Data - TTK 509 E; 512 E

Outline Dimensions and Data

Provides physical dimensions, connection sizes, and weight for TTK 509E/512E models.

Dimensional Data - TTK 518 E; 524 E; 530 E; 536 E

Outline Dimensions and Data

Provides physical dimensions, connection sizes, and weight for TTK 518E/524E/530E/536E models.

Typical Wiring Diagram

Wiring Diagram Explanation

Illustrates the electrical connections for all TTK models with component identification.

Wiring Interconnection - MCW, K, L Models

Single Power Supply

Shows wiring for MCW, K, L indoor units with a single power supply point.

Separate Power Supply

Shows wiring for MCW, K, L indoor units with separate power supply points for each unit.

Wiring Interconnection - MCW A Model

Single Power Supply

Shows wiring for MCW "A" indoor units with a single power supply point.

Separate Power Supply

Shows wiring for MCW "A" indoor units with separate power supply points for each unit.

Wiring Interconnection - MCX Models

Single Power Supply

Shows wiring for MCX indoor units with a single power supply point.

Separate Power Supply

Shows wiring for MCX indoor units with separate power supply points for each unit.

Wiring Interconnection - MCD Models

Single Power Supply

Shows wiring for MCD indoor units with a single power supply point.

Separate Power Supply

Shows wiring for MCD indoor units with separate power supply points for each unit.

Overview

This document is an installation manual for Trane Mini-Split System Condensing Units, specifically the TTK series, designed for horizontal air discharge. These units offer cooling capacities ranging from 9,000 to 36,000 BTU/h and operate on 50/60 Hz power.

Function Description

The Trane TTK series condensing units are part of a mini-split air conditioning system, primarily designed for cooling-only operation. They are manufactured under strict Trane Worldwide Quality Standards to provide comfortable and convenient cooling with minimal service requirements. The units are supplied pre-loaded with refrigerant from the factory and are pressure tested, dehydrated, and run tested before shipment to ensure proper operation.

Important Technical Specifications

Models Covered:

  • TTK 509 E
  • TTK 512 E
  • TTK 518 E
  • TTK 524 E
  • TTK 530 E
  • TTK 536 E

Nominal Capacity Class (BTU/h):

  • 09: 9,000 BTU/h
  • 12: 12,000 BTU/h
  • 18: 18,000 BTU/h
  • 24: 24,000 BTU/h
  • 30: 30,000 BTU/h
  • 36: 36,000 BTU/h

Refrigerant Type: R-22

Electrical Power Supply Characteristics:

  • 5: 1 Phase - 60 Hz - 208/230 VAC
  • B: 1 Phase - 50 Hz - 208/230 VAC

Agency Listing:

  • U: UL, ETL and ARI Standards
  • L: IRAM Standard

Optional Features:

  • A: with Multi-Function Service Valve and Orifice Kit

Refrigerant Line Connections: The units use flange thread-type connections for refrigerant lines. Specific torque values are provided for different piping diameters to ensure proper sealing:

  • 1/4" (6.35 mm): 150-200 kgf x cm (130-170 lbs x in.)
  • 3/8" (9.52 mm): 350-400 kgf x cm (300-340 lbs x in.)
  • 1/2" (12.7 mm): 500-550 kgf x cm (430-470 lbs x in.)
  • 5/8" (15.88 mm): 600-650 kgf x cm (520-570 lbs x in.)
  • 3/4" (19.05 mm): 700-750 kgf x cm (610-650 lbs x in.)

Additional Refrigerant Load (for line lengths exceeding 7.5 meters / 295.3"):

  • 1/4" - 1/2": 26 g/m (17.5x10⁻³ lbs/ft)
  • 1/4" - 5/8": 30 g/m (20.2x10⁻³ lbs/ft)
  • 3/8" - 5/8": 59 g/m (39.6x10⁻³ lbs/ft)
  • 3/8" - 3/4": 60 g/m (40.3x10⁻³ lbs/ft)
  • 3/8" - 7/8": 62 g/m (41.7x10⁻³ lbs/ft)
  • 3/8" - 1 1/8": 68 g/m (45.7x10⁻³ lbs/ft)

Dimensional Data (TTK 509E / TTK 512E):

  • Width: 700 mm (27.6")
  • Height: 500 mm (19.7")
  • Depth: 250 mm (9.8")
  • Weight: TTK 509E - 27 kg (60 lbs), TTK 512E - 32 kg (70.5 lbs)
  • Liquid Line: 1/4" (6.35 mm)
  • Suction Line: TTK 509E - 3/8" (9.5 mm), TTK 512E - 1/2" (13 mm)

Dimensional Data (TTK 518E / TTK 524E / TTK 530E / TTK 536E):

  • Width: 830 mm (32.7")
  • Height: 715.5 mm (28.2")
  • Depth: 330 mm (13.0")
  • Weight: TTK 518E - 48 kg (106 lbs), TTK 524E - 57 kg (126 lbs), TTK 530E - 67 kg (148 lbs), TTK 536E - 69 kg (153 lbs)
  • Liquid Line: TTK 518E - 1/4" (6.35 mm), TTK 524E/530E/536E - 3/8" (9.5 mm)
  • Suction Line: TTK 518E - 1/2" (12.7 mm), TTK 524E/530E - 5/8" (15.8 mm), TTK 536E - 3/4" (19.05 mm)

Usage Features

Installation Guidelines:

  • Foundation: Units must be installed on a leveled and reinforced concrete foundation, with a minimum height of 50 mm (1.97"). They should be fixed with bolts (not supplied).
  • Clearances:
    • Concrete foundation: at least 250 mm (9.84") away from walls or shrubbery.
    • Air inlet sides: minimum 250 mm (9.84").
    • Air discharge side: minimum 1200 mm (47.24").
    • Maintenance: minimum 300 mm (11.81") on one side.
    • Overall minimum clearance for proper ventilation: 600 mm (23.62") above the unit.
  • Roof Mounting: If mounted on a roof, ensure the roof can support the unit's weight. Proper vibration isolation is recommended.
  • Refrigerant Line Connection: Involves cutting and deburring tubes, insulating lines, flanging the tube ends, applying refrigerant oil, aligning and hand-tightening the nut, and finally tightening to specified torque values.
  • System Evacuation: Essential after installation to remove non-condensable gases and moisture. The system should be evacuated to 350 microns (5.9 x 10⁻² inHg). If the vacuum gauge reading exceeds 500 microns (8.3 x 10⁻² inHg) within one minute, it indicates incomplete evacuation or a system leakage.
  • Multi-Function Service Valve (Liquid Line): The units are supplied with a multi-function service valve and a restrictor kit. For indoor units without their own expansion device, the factory-installed passage orifice must be replaced with an appropriate restrictor from the kit, based on the indoor unit model.
  • Electrical Connections:
    • Wires from the compressor casing must not touch refrigerant tubes or the compressor.
    • Installation and grounding must comply with IEC 335-2-40: 2002 and local codes/NEC.
    • Power supply must match unit nameplate specifications.
    • An exclusive overcurrent protection circuit-breaker is required for the outdoor unit.
    • Flexible electric conduits are recommended where vibrations might introduce noise.
    • Appropriate color-coded wires should be used for command connections between indoor and outdoor units.
    • Wiring diagrams are provided for different indoor unit models (MCW, MCX, MCD) and power supply configurations (single power supply point for both units or for each unit).

System Start-Up: A comprehensive checklist is provided to ensure proper system operation:

  • Verify correct refrigerant and electric connections.
  • Check for foreign materials or tools on the equipment.
  • Check for possible leaks at connections.
  • Ensure lines are well insulated and passages through piping structure are insulated.
  • Verify free water drains.
  • Ensure insufflation and return grids are free and unobstructed, and air filters are clean.
  • Check thermostat accuracy with an inspected thermometer.
  • Confirm proper grounding.
  • Check power voltage, fuse/circuit-breaker ratings, and adequate wire sizes.
  • Verify tight field wiring connections and ensure electric wires do not touch refrigerant pipes.
  • Check remote control batteries.

Maintenance Features

The manual emphasizes the importance of proper installation and adherence to instructions to ensure the longevity and reliable operation of the unit. While specific maintenance schedules are not detailed in this installation manual, it highlights that the warranty is void if the equipment is modified or repaired without written approval from Trane, if operating limits are exceeded, or if the control system or electrical wiring is modified. It also states that damage due to inappropriate installation, lack of knowledge, or failure to comply with manufacturer's instructions is not covered by the warranty.

The document serves as a critical guide for qualified technicians to install the TTK series condensing units correctly, ensuring safety and optimal performance. It contains warnings and cautions to prevent potential hazards and ensure proper unit function.

Trane TTK 509 E Specifications

General IconGeneral
BrandTrane
ModelTTK 509 E
CategoryHeat Pump
LanguageEnglish