11
PUB. NO. 22-1802-03
Performance
Data
SW7 SW8 0.1 0.3 0.5 0.7 0.9
CFM 764 795 832 852 848
Temp. Rise 63 61 58 56 57
Watts 103 147 195 242 280
CFM 875 938 963 974 959
Temp. Rise 55 60 58 57 58
Watts 139 200 259 305 344
CFM 984 1029 1040 1039 980
Temp. Rise 49 47 46 46 49
Watts 185 253 304 347 357
CFM 1118 1138 1157 1125 1018
Temp. Rise 66 65 64 66 73
Watts 262 326 390 417 383
CFM 1310 1335 1277 1192 1097
Temp. Rise 57 55 58 62 68
Watts 411 498 498 472 441
CFM 1413 1399 1322 1233 1148
Temp. Rise 52 53 56 60 65
Watts 512 566 541 514 484
OFF
OFF
OFF
OFF
Heating
Heating
1st Stage
Heating
2nd
Stage
OFF
OFF
ON ON
ONLow
High
Low
Medium**
ON
ON
High
Medium** ON
*UD2B100AFV32A Furnace Heating Airflow (CFM) and Power (watts) vs. External Static Pressure With Filter
Airflow
Setting
Dip Switch Setting External Static Pressure
SW1 SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9
CFM 538
556 574 579 570
Watts 54
80 113 145 176
CFM 598
626 654 647 647
Watts 64
94 131 162 200
CFM 657
706 713 724 730
Watts 75
116 151 187 227
CFM 688
729 745 753 763
Watts 81
124 161 199 238
CFM 785
831 859 872 881
Watts 109
157 207 253 294
CFM 887
939 964 977 954
Watts 146
206 260 309 343
CFM 848
907 934 946 946
Watts 133
188 245 289 334
CFM 1018
1044 1055 1065 983
Watts 206
262 319 370 357
CFM 1139
1160 1184 1122 1020
Watts 274
344 411 417 386
CFM 1071
1089 1105 1108 1003
Watts 231
290 346 399 368
CFM 1208
1246 1249 1153 1060
Watts 323
411 469 441 410
CFM 1387
1383 1295 1221 1124
Watts 482
546 517 499 467
Notes:
1. * First letter may be "A" or "T".
2. ** Factory setting.
3. Continuous Fan Setting: Heating or cooling airflow is approximately 50% of selected cooling value.
4. For variable speed low speed airflows are approximately 30% of listed values.
5. LOW 350 cfm/ton is recommended for variable speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton;
HIGH 450 cfm/ton is for DRY CLIMATE setting.
Cooling
Unit
Outdoor
Low (350
CFM/Ton)
Normal (400
CFM/ton)
High (450
CFM/ton)
Low (350
CFM/Ton)
Airflow
Setting
Normal (400
CFM/ton)
High (450
CFM/ton)
Low (350
CFM/Ton)
Normal (400
CFM/ton)
High (450
CFM/ton)
OFF OFF OFF
Low (350
CFM/Ton)
Normal (400
CFM/ton)
High (450
CFM/ton)
OFF OFF
ON OFF
3.0**
2.5
2
1.5
OFF
OFF OFF ON
OFFOFF
OFF
ONOFFOFF
OFF
OFFONOFF
ON
OFF
ON
OFFOFFON
ON OFF
OFF
ONOFFON
ON ON
OFF
OFFONON
*UD2B100AFV32A Furnace Cooling Airflow (CFM) and Power (Watts) vs. External Static Pressure With Filter
Dip Switch Setting External Static Pressure
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON