EasyManua.ls Logo

Trane TUH1C100A9481A

Trane TUH1C100A9481A
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18-CD29D1-11 39
Installer’s Guide
TABLE 21
INTEGRATED FURNACE CONTROL ERROR FLASH CODES
Flashing Slow --- Normal - No call for Heat
Flashing Fast --- Normal - Call for Heat
Continuous ON --- Replace IFC
Continuous OFF --- Check Power
2 Flashes --- System Lockout (Retries or Recycles exceeded)
3 Flashes ---
Draft Pressure Error - Possible problems
a) Venting problem
b) Pressure switch problem
c) Inducer problem
4 Flashes --- Open High Limit Device
5 Flashes --- Flame sensed when no flame should be present
6 Flashes --- 115 Volt AC power reversed or Poor Grounding
7 Flashes --- Gas valve circuit error
8 Flashes --- Low flame sense signal
9 Flashes ---
Check Ignitor circuit and Line "N" to 24VAC "Com-
mon" voltage (< 2volts)
(possible grounding problem)

Table of Contents

Related product manuals