EasyManua.ls Logo

Trane UC1B060A9361A series - User Manual

Trane UC1B060A9361A series
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
*UC1B040A9241A
*UC1B060A9361A
*UC1B080A9421A
*UC1C100A9481A
Upflow/ Horizontal and Downflow/ Horizontal
Gas-Fired Condensing Furnaces
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANT This Document is customer property and is to remain with this unit.
Please return to service information pack upon completion of work.
Installer’s Guide
*UC1D100A9601A
*UC1D120A9601A
*DC1B040A9241A
*DC1B060A9361A
*DC1B080A9421A
*DC1C100A9481A
*DC1D120A9601A
*__First letter may be “A” or “T”
A341624P01
1
11
18
88
8-
--
-C
CC
CD
DD
D1
11
19
99
9D
DD
D5
55
5-
--
-2
22
25
55
5
UPFLOW
*UC1
UPFLOW/ HORIZONTAL
*DC1
DOWNFLOW
DOWNFLOW/ HORIZONTAL
Question and Answer IconNeed help?

Do you have a question about the Trane UC1B060A9361A series and is the answer not in the manual?

Trane UC1B060A9361A series Specifications

General IconGeneral
Model NumberUC1B060A9361A
CategoryFurnace
Ignition TypeHot Surface Ignition
Fuel TypeNatural Gas
Input BTU60000
Stages1
Warranty5-Year parts
Blower TypeMulti-speed
Output BTU57, 000 BTU/hr
Heating Capacity57, 000 BTU/hr

Summary

SAFETY INFORMATION

Safety Practices and Precautions

Essential safety guidelines for installation, servicing, and operation of the furnace.

Carbon Monoxide Poisoning Hazard

Critical warning about CO poisoning risk due to improper venting procedures.

GENERAL INSTALLATION GUIDELINES

Fire or Explosion Hazard Warning

Warns of serious injury, death, or property damage from improper handling or servicing.

LOCATION AND CLEARANCES

Furnace Installation Location Requirements

Criteria for selecting the furnace installation site for optimal performance and accessibility.

Clearance Requirements for Safety

Specifies minimum clearances to combustible materials for safe operation.

COMBUSTION AND VENTILATION AIR

Airflow for Combustion and Ventilation

Details airflow needs and potential obstructions for safe furnace operation.

Confined vs. Unconfined Space Air Supply

Explains air supply requirements for different installation space types.

FILTER SPECIFICATIONS AND CLEARANCES

Minimum Clearances to Combustibles

Table specifying required clearances for furnaces in different locations.

GENERAL VENTING AND MATERIALS

Positive-Pressure Vent System Characteristics

Explains Category IV venting system features like positive pressure and tightness.

VENTING TABLES AND TERMINAL CLEARANCES

Upflow;Horizontal Venting Length Limits

Maximum allowable vent and inlet pipe lengths for upflow/horizontal configurations.

Downflow;Horizontal Venting Length Limits

Maximum allowable vent pipe lengths for downflow/horizontal configurations.

Vent Terminal Clearance Requirements

Specifies clearances required for direct and non-direct vent terminals based on location.

SPECIAL VENTING REQUIREMENTS AND KITS

Massachusetts Side Wall Venting Rules

Specific MA requirements for CO detectors and signage for side wall vented appliances.

CONDENSATE DRAINAGE MANAGEMENT

ELECTRICAL CONNECTIONS AND WIRING

FURNACE TWINNING AND GAS SAFETY

Propane Gas Safety Warning

Critical safety warning regarding propane gas hazards, especially in low areas.

GAS PIPING AND ADJUSTMENTS

START-UP, LIGHTING, AND OPERATION

CONTROL LIMITS, AIRFLOW, AND ABNORMAL CONDITIONS

Furnace Abnormal Conditions and Troubleshooting

Lists common furnace issues like flame loss, power failure, and their resolutions.

FURNACE ERROR CODE DIAGNOSTICS

Integrated Furnace Control Error Codes

Table listing error flash codes and their troubleshooting meanings for diagnostics.