EasyManua.ls Logo

Trane UC1C100A9481A series - User Manual

Trane UC1C100A9481A series
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
*UC1B040A9241A
*UC1B060A9361A
*UC1B080A9421A
*UC1C100A9481A
Upflow/ Horizontal and Downflow/ Horizontal
Gas-Fired Condensing Furnaces
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANT This Document is customer property and is to remain with this unit.
Please return to service information pack upon completion of work.
Installer’s Guide
*UC1D100A9601A
*UC1D120A9601A
*DC1B040A9241A
*DC1B060A9361A
*DC1B080A9421A
*DC1C100A9481A
*DC1D120A9601A
*__First letter may be “A” or “T”
A341624P01
1
11
18
88
8-
--
-C
CC
CD
DD
D1
11
19
99
9D
DD
D5
55
5-
--
-2
22
25
55
5
UPFLOW
*UC1
UPFLOW/ HORIZONTAL
*DC1
DOWNFLOW
DOWNFLOW/ HORIZONTAL
Question and Answer IconNeed help?

Do you have a question about the Trane UC1C100A9481A series and is the answer not in the manual?

Trane UC1C100A9481A series Specifications

General IconGeneral
CategoryFurnace
Fuel TypeNatural Gas
Ignition TypeHot Surface Ignition
Heat Exchanger MaterialAluminized Steel
Input BTU100, 000 BTU/h
Stages1

Summary

SAFETY SECTION

Carbon Monoxide Poisoning Hazard

Warns about carbon monoxide risks and outlines safe operation steps.

GENERAL INSTALLATION INSTRUCTIONS

Fire or Explosion Hazard Warning

Warns about potential fire and explosion hazards from improper servicing or operation.

LOCATION AND CLEARANCES

AIR FOR COMBUSTION AND VENTILATION

GENERAL VENTING

Venting System Requirements

Details requirements for venting, materials, and classification (Category IV).

VENT AND INLET AIR CONNECTIONS

Maximum Vent Lengths (Upflow;Horizontal)

Provides maximum vent lengths for upflow/horizontal installations by pipe size and model.

MAXIMUM VENT LENGTHS

Downflow;Horizontal Venting Table

Lists maximum vent lengths for downflow/horizontal setups by pipe size and model.

TERMINAL CLEARANCES

Direct Vent Terminal Clearances

Details required clearances for direct vent terminals in Canada and US.

Non-Direct Vent Terminal Clearances

Details required clearances for non-direct vent terminals in Canada and US.

HORIZONTAL VENTING CONFIGURATIONS

Venting Through Walls

Provides guidelines for horizontal wall venting, including terminal placement and insulation.

MASSACHUSETTS SPECIFIC REQUIREMENTS

Carbon Monoxide Detector Installation

Details mandatory installation of CO detectors for side wall vented appliances.

Signage and Inspection Compliance

Covers required signage and inspection compliance for installations.

CONDENSATE DRAIN INSTRUCTIONS

ELECTRICAL CONNECTIONS

Wiring Diagram for 1 Stage Heating

Illustrates the field wiring connections for a single-stage heating furnace setup.

ELECTRICAL WIRING DIAGRAMS

GAS PIPING

Installation Codes and Drip Leg Requirements

Covers gas piping codes, drip leg installation, and pressure testing disconnection.

COMBUSTION AND INPUT CHECK

Gas Flow Calculation and Valve Adjustment

Explains how to check gas flow, calculate input, and adjust the gas valve.

GAS PRESSURE AND HIGH ALTITUDE ADJUSTMENTS

High Altitude Derating Procedure

Explains derating furnace input for installations at higher altitudes.

REINSTALLATION AND START-UP

Preliminary Inspections for Start-Up

Outlines the necessary checks before initiating furnace operation.

OPERATION AND CONTROL CHECKS

ADJUSTMENTS AND TROUBLESHOOTING

Burner Box Limit Device & Abnormal Conditions

Explains the burner box limit device and lists common abnormal operating conditions.

SYSTEM RESET AND SAFETY PRECAUTIONS

TROUBLESHOOTING ERROR CODES

Integrated Furnace Control Flash Codes

Lists and explains error codes generated by the integrated furnace control module.

Related product manuals