Do you have a question about the Transtecno CM 040 and is the answer not in the manual?
Highlights potential hazards associated with rotating, moving, exposed, or hot parts of the gearmotor during operation.
Explains the severe consequences of improper use or failure to follow manual instructions, including injury or death.
Covers critical pre-installation checks including product matching, surface preparation, alignment, and safety guards.
Instructions for mounting a motor without a coupling, focusing on shaft/flange tolerances, cleaning, and alignment.
Guidance on mounting motors with couplings for specific gearbox series, emphasizing proper assembly and tightening.
Provides a table of screw tightening torques for various screw sizes (M6 to M24) with property class 8.8.
Instructions for fitting devices onto solid input/output shafts, including lubrication, avoiding hammering, and using mounting tools.
Guidelines for fitting devices onto hollow output shafts, emphasizing corrosion-protection lubricants and proper assembly tools.
Guidance on mounting shrink disks for ATS, ITB, ITS gearmotors, covering degreasing, screw tightening, and alignment.
Lists approved lubricants for Transtecno gearmotors and variable speed drives, categorized by brand and type.
Provides tables detailing the oil quantities required for CMG and CMB gearmotors across different mounting positions.
Covers residual risks before commissioning, including oil level checks, leak checks, mounting position verification, and motor voltage.
Details the start-up procedure, emphasizing gradual load application and the non-essential nature of running-in for modern gearmotors.
Provides a troubleshooting guide for common operational problems like motor not starting or excessive temperature, with potential causes and actions.
Highlights the low maintenance requirement due to high internal finish quality, outlining general rules for checks and precautions before maintenance.
Details inspection and maintenance intervals (3000h/6m, 10000h) for checks like noise, leaks, oil level, surfaces, and lubricant replacement.
Step-by-step guide for lubricant replacement, including safety rules, plug positions, oil draining, and correct oil quantity.
Lists Transtecno gearmotor series available with ATEX compliance and general instructions for verification and installation.
Details ATEX gearmotor installation checks, including paintwork, cleanliness, nameplate visibility, and environmental conditions.
Specific start-up procedures for ATEX gearmotors, focusing on surface temperature checks and ambient temperature limits.