DISPLAY SCREEN DESCRIPTION OF SIGNALS AND POSSIBLE SOLUTIONS
Heater ow is
reduced
(HFL) - M016
Problem description: there may not be enough water ow through the
heater to carry the heat away from the heating element. Heater start up
will begin again after about 1 min. See “Flow Related Checks” below.
Heater ow is
reduced
(LF)* - M017
Problem description: there is not enough water ow through the heater
to carry the heat away from the heating element and the heater has been
disabled. See “Flow Related Checks” below. After the problem has been
resolved, you must press any button to reset and begin heater start up.
The heater may
be dry (dr)* -
M028
Problem description: Possible lack of water in the heater. Each pool
function is disabled for 15 minutes. Press any button to re-enable the
heater operation and reset the error. See “Flow Related Checks” below.
The heater is dry*
- M027
Problem description: not enough water in the heater. All minipool
functions are disabled. After solving the problem, remove and restore
the power to initialize the water heating procedure. See “Flow Related
Checks” below.
The heater is
too hot (OHH)* -
M030
Problem description: the water temperature sensors have detected too
high temperatures, 47.8°C (118°F). All minipool functions are disabled.
Press any button on the control panel to re-enable the heater opera-
tion when the water temperature is below 42.2 °C (108 °F). See “Flow
Related Checks” below.
A reset message
can accompany
other messages
Problem description: some errors may require power to be cut off and
then restored.
* this message can be deleted from the top of the panel by pressing any key.
More information
PROBLEMS CONNECTED TO THE WATER FLOW
Check that the water level is not too low, the suction ow is not blocked, the valves are working, the air is not
trapped, the jets and pumps are ready.
In some systems, even when the pool is switched off, some functions occasionally activate to continue monitoring
the temperature or the need to activate frost protection.
* This message can be reset from the topside panel with any button press.