80
EN
minipool Quarz
Use
MESSAGES
CONNECTED TO
THE SENSORS
DISPLAY SCREEN DESCRIPTION OF SIGNALS AND POSSIBLE SOLUTIONS
Temperature
sensor not
accurate - M015
Problem description: the temperature sensors may be out of sync by
3°F. Call for Service.
Temperature
sensor not
accurate - M026
Problem description: the temperature sensors ARE out of sync. The
Sensor Balance is Poor fault has been established for at least 1 hour.
Call for Service.
Sensor fault -
Sensor A: M031,
Sensor B: M032
Problem description: A temperature sensor or sensor circuit has failed.
Call for Service.
VARIOUS TYPES
OF MESSAGES
DISPLAY SCREEN DESCRIPTION OF SIGNALS AND POSSIBLE SOLUTIONS
No signal
Problem description: the control panel is not communicating with the
control unit. Call for Service.
Development
software (beta)
Problem description: the control system is operating with test software.
Call for Service.
°F or °C are
replaced by °T
Problem description: the control system is in test mode. Call for Service.
* this message can be deleted from the top of the panel by pressing any key.
* this message can be deleted from the top of the panel by pressing any key.