16
EN
Muse - Maya - Wave minipool
Use
FILTERING
FUNCTION
FLT
EXAMPLE:
access to programming
tasto
nascosto
Setting the duration of
ltering (in the example d3=
3 hours)
conrm duration set
Setting hours of delay to
start (in the example S4=
4 hours)
conrm delay set
In this example, if at the
time of programming it is
4 pm, the function - lasting
3 hours - will start at 8 pm
(i.e., 4 hours later), then
at 8 am, then again at 8
pm and so on, with a non-
variable frequency of 12
hours between one ltering
and the other.
Filtering is used to lter and sanitise water by sequentially
activating water pumps, blowers (if present) and recirculation
pumps. When active, the display shows the message "FLT"
alternating with the water temperature.
If a user starts a function (e.g., the whirlpool) while the ltering
function is also active, the ltering function is temporarily
interrupted and starts again 15 minutes after the function
started by the user is turned off.
There are 2 lterings per day having a default duration of 2
hours each (duration that can be set by the user), 12 hours
apart from each other (non-variable value).
Change the factory settings (two lterings per day lasting two
hours each) only if necessary.
PROGRAMMING
• Press the "hidden" key (
located below the display, even
if it is not visible it is active)
and then, within three seconds,
the
+
key.
• The display shows the word "dx", where "x" indicates the
duration in hours of ltering
(e.g., d2 = 2 hours of ltering
- default value)
.
• Set the desired duration with
+
or
-
(valid values from
0 (no ltering) to 12h (continuous ltering)
;
• Press the key to start the entered value.
• After the key is pressed the new ltering time is stored and
the next parameter is set, i.e., after how many hours from
the programming the function must start.
• The display shows the message “Sx”, where “x” indicates
the hours of delay
(e.g., S4= the function will start after 4
hours from the hour in which the programming is being
done).
• Set the value desire using the
+
or
-
keys (valid range:
from
0
(ltering starts immediately after programming) to 12h
(ltering will start after 12 hours)
.
• Press the key to start the entered value.
Once programmed, the function starts after the set delay and
will be repeated every 12 hours for the duration set.