SECTION VI - Internal Wiring
ELECTRICAL SHOCK HAZARD. For
your safety, disconnect electrical power
supply to the appliance before servicing
or making any electrical connections to
avoid possible electric shock hazard.
Failure to do so can cause severe person-
al injury or death.
Prior to servicing label all wires before
disconnection. Wiring errors can cause
improper and dangerous operation.
Verify proper operation after servicing.
General Requirements
- Wiring must be N.E.C Class 1.
- If original wiring installed in the appli-
ance must be replaced, use only type T,
90ºC wire or equivalent.
- The MODULATING DELTA must be
electrically grounded as required by
National Electrical Code ANSI/NFPA
70 and/or CSA C22.1 Canadian
Electrical Code - latest edition(s).