Parameter 35 has multiple parameter settings
available in addition to the settings 12 and 13,
which are outlined in detail in this supplement
guide. DO NOT set Parameter 35 to any other
setting other than 12 or 13. Failure to comply
can result in erratic or unreliable operation of the
Prestige boiler.
WARNING
Parameter Description
Factory
Setting
Minimum
Setting
Maximum
Setting
33
Set value addition for DHW. This value is added
to Parameter 1 to set the operating temperature
of the Prestige during a DHW request. See
pages 6 through 9 for additional information
46ºF 00ºF 54ºF
35
See Warning
Below
Selection of the DHW application. Storage tank
application with NTC sensor (12). Storage tank
with aquastat control application (13).
13 00 29
See pages 6 through 9 for additional information

Other manuals for TriangleTube prestige

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TriangleTube prestige and is the answer not in the manual?

TriangleTube prestige Specifications

General IconGeneral
ManufacturerTriangle Tube
EfficiencyUp to 95% AFUE
Heat Exchanger MaterialStainless Steel
Vent TypeDirect Vent
ModelPrestige
CategoryBoiler
Fuel TypeNatural Gas, Propane
ModulationYes
Boiler TypeCondensing
WeightVaries by model
DimensionsVaries by model
Warranty10 years heat exchanger

Related product manuals